Service manual

______________________________
CHANGEOVER INSTRUCTIONS
BLOW BOX PEEL EDGE CHANGEOVER
1) Remove the label sensor from the peel edge assembly and remount on the opposite side making sure
that the fiber cables are threaded through from the opposite side. The open end of the U-shaped sensor
should face towards the inside.
2) Remove the guide rollers and remount to the opposite side of the peel edge mounting plate.
3) Remove the peel edge and remount to the opposite side of the mounting plate using the tapped holes on
the other end of the peel edge. Make sure the beveled edge is down and facing the same direction as it
was originally.
4) Remove the label tension spring mounting bar and remount on the opposite side. The tension spring
and the adjustment stop must be reversed on the mounting bar as well.
5) Remove the air assist tube and insert through the opposite side of the mounting plate and re-attach.
BLOW BOX GRID/FAN ASSEMBLY CHANGEOVER
1) Remove the air blast fitting from the back of the nose assembly mounting plate and set aside.
2) Loosen the two knurled knobs on the back of the fan box and lock it in the upright position.
3) Remove the air blast manifold, label grid, and the air jet storage block. Remount on the opposite side of
the nose assembly mounting plate.
4) Pull the fan wiring harness through the slotted opening in the nose mounting plate.
5) Remove the four screws holding the fan box hinge to the mounting plate and remount the fan box on the
opposite side of the nose mounting plate.
6) Push the fan wiring harness through the slotted opening from the opposite side.
7) Re-install the air blast fitting in the nose assembly mounting plate.
102