Service manual
______________________________
CHANGEOVER INSTRUCTIONS
NOSE ASSEMBLY CHANGEOVER
When changing the nose assembly to the opposite hand dispense, all parts are first transferred to the
opposite side of the mounting plate. Then the entire nose assembly is rotated 180 degrees and remounted to
the opposite side of the applicator.
1) Remove the peel edge assembly from the nose assembly mounting plate. On a merge applicator, note
the position of the bronze washers between the mounting plate and the peel edge assembly.
2) Change the applicator peel edge assembly to the opposite hand dispense (See: “APPLICATOR” PEEL
EDGE CHANGEOVER).
3) Re-mount the peel edge assembly to the opposite side of the nose assembly mounting plate. On a merge
applicator, re-install the bronze washers between the peel edge assembly and the mounting plate.
4) If the applicator is an air blow, change the blow box grid/fan to the opposite hand dispense (See:
BLOW BOX GRID/FAN ASSEMBLY CHANGEOVER).
4) If the applicator is a tamp, change the tamp assembly to the opposite hand dispense (See: TAMP
ASSEMBLY CHANGEOVER).
5) Remove the tension brush assembly and reassemble on the opposite side of the nose mounting plate.
MERGE PEEL EDGE CHANGEOVER
1) Remove the label sensor from the peel edge and remount on the opposite side rail. The open end of the
U-shaped sensor should face towards the inside.
101