Instruction manual
C.Scope Cable Avoidance Tool: Function Checks
Generator Mode - Locate an outdoor test area that is free from extraneous fields
resulting from overhead and underground cables. The area should also not be near
fences, steel framed buildings, or on reinforced concrete as the signal will be reduced.
Place the Signal Generator on the ground in the normal orientation and switch on - a
tone should be heard. Set to Continuous and ensure highest output power is selected.
With the C.Scope Cable Avoidance Tool in the orientation shown, and Sensitivity rotated
fully clockwise, the results indicated should be obtained.
DISTANCE MODE AUDIO METER
6metres Generator Present Full scale
12metres Generator Less than at 6m Less than Full scale
6metres Radio Present
6metres Power None None
34