GE Medical Systems Technical Publications Direction 2303347 Revision 2.7 SIGNA PROFILE 7.71 CONFORMANCE STATEMENT for DICOM v3.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 blank page doc ver 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 TABLE OF CONTENTS 1 2 SECTION 1 - INTRODUCTION 1.0 Overview 7 1.1 Overall Conformance Statement Documentation Structure 8 1.2 Intended Audience 11 1.3 Scope and Field of Application 11 1.4 Important Remarks 12 1.5 References 13 1.6 Definitions 13 1.7 Symbols and Abbreviations 13 SECTION 2 - NETWORK CONFORMANCE STATEMENT 2.0 3 7 INTRODUCTION 14 14 2.1 IMPLEMENTATION MODEL 2.1.
GE Medical Systems REV 2.7 3.0 4 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Introduction 39 3.1 Implementation Model : MOD Archive Server 3.1.1 Application Data Flow Diagram 3.1.2 Functional Definitions of AE's 3.1.3 Sequencing of Real World Activities 3.1.4 File Meta Information for Implementation Class and Version 39 39 40 40 40 3.2 AE Specifications 3.2.1 MOD Archive Specification 40 41 3.3 Standard, Augmented and Private Application Profiles 3.3.1 Class and Profile Identification 3.3.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 APPENDIX B PRIVATE DATA ELEMENTS 71 APPENDIX C DICOMDIR DIRECTORY INFORMATION 82 doc ver 2.
GE Medical Systems REV 2.7 WARNING SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 • THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY. • IF A CUSTOMER’S SERVICE PROVIDER REQUIRES A LANGUAGE OTHER THAN ENGLISH, IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE TRANSLATION SERVICES. • DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THE SERVICE MANUAL HAS BEEN CONSULTED AND UNDERSTOOD.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 1 SECTION 1 - INTRODUCTION 1.0 Overview This DICOM Conformance Statement is divided into Sections as described below: Section 1, Introduction, which describes the overall structure, intent, and references for this Conformance Statement Section 2, Network Conformance Statement, which specifies the GEMS equipment compliance to the DICOM requirements for the implementation of Networking features.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 1.1 Overall Conformance Statement Documentation Structure The Documentation Structure of the GEMS Conformance Statements and their relationship with the DICOM v3.0 Conformance Statements is shown in Illustration below. doc ver 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 ID/Net v3.0 Introduction to the Integrated DICOM/Network v3.0 (ID/Net v3.0) Conformance Statement Direction: 2118780 APPLICATION ENTITY SPECIFICATION (SERVICE CLASSES, INFORMATION OBJECTS, MESSAGE EXCHANGES, ETC.) Product Implementation: CT Advantage Conformance MR Advantage Statement Conformance Direction: SIGNA PROFILE Statement Conformance Direction: Statement Direction: 2285230 ...... Conformance Statement Direction: ......
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 This DICOM Conformance Statement documents the DICOM v3.0 Conformance Statement and Technical Specification required to interoperate with the GEMS network interface. Introductory information, which is applicable to all GEMS Conformance Statements, is described in the document: Introduction to the Integrated DICOM/Network v3.0 (ID/Net v3.0) Conformance Statement Direction: 2118780.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 1.2 Intended Audience The reader of this document is concerned with software design and/or system integration issues. It is assumed that the reader of this document is familiar with the DICOM v3.0 Standards and with the terminology and concepts which are used in those Standards. If readers are unfamiliar with DICOM v3.0 terminology they should first refer to the document listed below, then read the DICOM v3.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 1.4 Important Remarks The use of these DICOM Conformance Statements, in conjunction with the DICOM v3.0 Standards, is intended to facilitate communication with GE imaging equipment. However, by itself, it is not sufficient to ensure that inter-operation will be successful.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 1.5 References A list of references which is applicable to all GEMS Conformance Statements is included in the Introduction to the Integrated DICOM/Network v3.0 (ID/Net v3.0) Conformance Statement, Direction: 2118780. 1.6 Definitions A set of definitions which is applicable to all GEMS Conformance Statements is included in the Introduction to the Integrated DICOM/Network v3.0 (ID/Net v3.0) Conformance Statement, Direction: 2118780.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 2 SECTION 2 - NETWORK CONFORMANCE STATEMENT 2.0 INTRODUCTION This Conformance Statement (CS) specifies the SIGNA PROFILE compliance to DICOM v3.0. It details the DICOM Service Classes and roles which are supported by this product in it’s version 7.71. The SIGNA PROFILE product uses DICOM services to import images for possible further analysis and/or processing.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 2.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Real-World Activity, Choose DICOM Ping, consists of an operator selecting DICOM Ping from the “Network” pull down menu on the local database manager to check the status of the selected remote DICOM AE. There is no Real-World activity required for the DICOM Server AE to respond to an incoming DICOM store, query or retrieve. The DICOM Server AE is always prepared to respond to a DICOM Store, Query, or Retrieve by any remote DICOM AE.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 • RSP message. The Remote AE can terminate the query by sending a CCANCEL-FIND-RQ message. Retrieve: If a C-MOVE-RQ message is received the DICOM Server AE will lookup its list of configured Remote AEs for the Destination AE. If the Destination AE is configured, the DICOM Server AE will open a new association to the Destination AE and use C-STORE-RQ to send the image(s).
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 2.2.1.1 Association Establishment Policy 2.2.1.1.1 General The DICOM Application Context Name (ACN), which is always proposed, is: Application Context Name 1.2.840.10008.3.1.1.1 The Maximum Length PDU negotiation is included in all association establishment requests. The maximum length PDU for association initiated by the DICOM Server AE is: Maximum Length PDU 36 Kbytes SOP class Extended Negotiation is not supported.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 2.2.1.2 Association Initiation by Real-World Activity This AE attempts to initiate a new association due to a “Push” operation initiated by the user. A new association is also initiated when the user performs a “Query Remote” operation or issues a retrieve operation by performing a “Get” operation at Study/Series/Image level. 2.2.1.2.1 Push Image(s) to Remote AE 2.2.1.2.1.
GE Medical Systems REV 2.7 CT Image Storage MR Image Storage MR Image Storage Secondary Capture Secondary Capture Stand-alone Overlay Stand-alone Overlay Study Root Query/Retrieve FIND Study Root Query/Retrieve MOVE SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 1.2.840.10008.5.1.4.1.1.2 1.2.840.10008.5.1.4.1.1.4 1.2.840.10008.5.1.4.1.1.4 1.2.840.10008.5.1.4.1.1.7 1.2.840.10008.5.1.4.1.1.7 1.2.840.10008.5.1.4.1.1.8 1.2.840.10008.5.1.4.1.1.8 1.2.840.10008.5.1.4.1.2.2.1 1.2.840.10008.5.1.4.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Each C-STORE operation supports an “Association Timer”. This timer starts when the association request is sent and stops when the association is established or rejected. The time-out is configurable in dcs.cfg as bi_assoc_tio and defaults to 30 seconds. Each C-STORE operation also supports an “Operation Inactivity Timer”.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 selects a range type from the “Exam date” pull down menu, where the choices are All, Before, Between, or Exactly. Once a range type is selected, the correct number of fields appear and the operator enters dates into those fields. Once the desired parameters are entered the operator chooses “OK” and that will cause the DICOM Server AE to initiate an association to the selected Remote AE.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Description Study date Type R Tag 0008,0020 Study time Accession number R R 0008,0030 0008,0050 Patient’s name R 0010,0010 Study id R 0020,0010 Study Instance UID U 0020,000D Study description Private Creator Identification Suite Id O P P 0008,1030 0009,0010 0009,1002 Value Zero length for any Study date, or “yyyymmdd-yyyymmdd” matches inclusive range of ‘from-to’ Study dates.
GE Medical Systems REV 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 When the Real-World activity “Get” is initiated all presentation contexts shown in table 2.2.1.2.1.2-1 are proposed during association establishment, but only the Query/Retrieve-MOVE related contexts are applicable to this activity. 2.2.1.2.3.2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 2.2.1.2.4.2.1 SOP Specific Conformance Statement to Verification SOP Class The DICOM Server AE provides standard conformance to the DICOM Verification Service Class. Each ECHO operation supports an “Association Timer”, ”Operation Inactivity Timer” and “Session Timer” with a time out values of 300 seconds, 90 seconds and 60 minutes respectively.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Name UID Name List UID List Verification 1.2.840.10008.1.1 1.2.840.10008.1.2 SCP None CT Image Storage 1.2.840.10008.5.1.4.1.1.2 1.2.840.10008.1.2 SCP None CT Image Storage 1.2.840.10008.5.1.4.1.1.2 1.2.840.113619.5.2 SCP None CT Image Storage 1.2.840.10008.5.1.4.1.1.2 1.2.840.10008.1.2.1 SCP None CT Image Storage 1.2.840.10008.5.1.4.1.1.2 1.2.840.10008.1.2.2 SCP None MR Image Storage 1.2.840.10008.5.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 • A711 (Out of Resources) Indicates that probably there was not enough disk space to store the image. The user should attempt recovery by removing some images from the SIGNA PROFILE system. • A712 (Out of Resources) Indicates that there was not enough resource (such as memory) to store the image. • A800 (SOP Class not supported) In the event of a successful C-STORE operation, the image has successfully been written to disk.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 2.2.1.3.2 Verification Request from Remote AE This AE is indefinitely listening for associations. No operator action is required to respond to a verification message. 2.2.1.3.2.1 Associated Real-World Activity The Real-World Activity associated with the verification request is to send a CECHO response message with a status of “success” to the requesting AE. 2.2.1.3.2.2 Presentation Context Table Table 2.2.1.3.2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Table 2.2.1.3.1.2-1: Acceptable Presentation Contexts for DICOM Server AE and Real-World Activity Query Request Abstract Syntax Presentation Context Table Transfer Syntax Name UID Name List UID List Study Root Query/Retrieve FIND 1.2.840.10008.5.1.4.1.2.2.1 Implicit VR Little Endian 1.2.840.10008.1.2 Role Extended Negotiation SCU None 2.2.1.3.3.2.
GE Medical Systems REV 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 If the database does not have a value corresponding to any requested optional key a zero-length element will be returned. Except sequence matching all other matchings are supported. Only hierarchical query is supported. Therefore, the C-FIND SCP will not perform any extended negotiation. 2.2.1.3.4 Retrieve Request From Remote AE This AE is indefinitely listening for associations.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 SOP Class Name CT Image Information Storage MR Image Information Storage Secondary Capture image storage Standalone Overlay storage SOP Class UID 1.2.840.10008.5.1.4.1.1.2 1.2.840.10008.5.1.4.1.1.4 1.2.840.10008.5.1.4.1.1.7 1.2.840.10008.5.1.4.1.1.8 In addition to the C-MOVE response status values defined in DICOM V3.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 2.3 COMMUNICATION PROFILES 2.3.1 Supported Communication Stacks (parts 8,9) DICOM Upper Layer (Part 8) is supported using TCP/IP. 2.3.2 TCP/IP Stack The TCP/IP stack is inherited from a UNIX Operating System. 2.3.2.1 Physical Media Support Ethernet v2.0, IEEE 802.3. 2.3.3 Point-to-Point Stack A 50-pin ACR-NEMA connection is not applicable to this product. doc ver 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 2.4 EXTENSIONS / SPECIALIZATIONS / PRIVATIZATIONS 2.4.1 Specialized Information Object Definition Following is a list of additional private attributes defined for a standard MR IOD. For incoming third-party DICOM images the values in these elements are retained without modification.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 RAMP_PA_GEMS RAMP_SI_GEMS RAMP_IS_GEMS FC_FREQ_AX_GEMS FC_SLICE_AX_GEMS SS_GEMS VASCANGIO_GEMS RESP_GEMS BC_GEMS Z1024_GEMS CC_GEMS Z512_GEMS Z2_GEMS Z4_GEMS FR_GEMS BSP_GEMS FWF_GEMS FWW_GEMS T2P_GEMS SSRF_GEMS RTBC_GEMS AN_GEMS Note: When converting a received DICOM IOD to Advantage format if element 18,22 does not contain any of the defined values the received data will be interpreted as having the value “NONE”. 2.4.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Presentation Context Table - Accepted / Proposed Abstract Syntax Transfer Syntax Role Extended Negotiation Name UID Name List UID List GE Private DICOM MR Image Information Object (ID/Net v2.0 compatible) GE Private DICOM MR Image Information Object (ID/Net v2.0 compatible) GE Private DICOM CT Image Information Object (ID/Net v2.0 compatible) GE Private DICOM CT Image Information Object (ID/Net v2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 2.4.4 Private Data Elements Refer to Appendix B for a complete listing of private data elements used with this implementation. 2.5 CONFIGURATION 2.5.1 AE Title/Presentation Address Mapping The SIGNA PROFILE system allows the user to “add”, “Remove”, or “Update” the mapping of remote AE Titles to IP Addresses and Ports.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 3 MEDIA STORAGE CONFORMANCE STATEMENT 3.0 Introduction This Conformance Statement (CS) specifies the SIGNA PROFILE compliance to DICOM v3.0 Media Interchange. It details the DICOM Media Storage Application Profiles and roles which are supported by this product in it’s version 7.71. Note the format of this section follows the format of the DICOM Standard Part 2 (conformance) Annex C hence the paragraph numbering scheme.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 The MOD Archive Server AE can initialize Media by acting as an FSC to create a new DICOM File-set on a 2.3 GB MOD media or a 1.2GB MOD media. It initializes the DICOM File-set and writes the specified SOP instances onto the MOD. The SOP instances written will be limited to instances that match the criteria of one of the Application Profiles that is supported.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 3.2.1 MOD Archive Specification The MOD Archive provides standard conformance to DICOM Interchange Option of the Media Storage Service Class. The Application Profiles and roles are listed in Table 3.2-1. Table 3.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 The MOD Archive Application will label the media and take the user provided list of SOP instances eliminating any SOP instances on that list that does not correspond to one of the Application Profiles in Table 3.2-1. These SOP instances are written to the media and a corresponding DICOMDIR is created.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 3.2.1.2.4 Real World Activity: Update MOD The MOD Archive Application acts as an FSU using the Interchange option when requested to update an MOD. The MOD Archive Application will take the selected list of SOP instances and eliminate any SOP instance that does not correspond to permissible SOP instances listed in the Application Profiles Table 3.2-1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 This Application Profile facilitates the interchange of primary CT and MR images as well as processed CT and MR images as Secondary Capture and Standalone Overlay Images. Please refer to appendix A for the IOD definitions. CT, MR, SC and OV images may co-exist within the same File-set. Typical interchanges would be between acquisition devices, archives and workstations within and between institutions. 3.3.2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 3.3.3.1 STD-CTMR-MOD12 Class Profile 3.3.3.1.1 SOP Classes and Transfer Syntaxes This class of Application Profiles is based on the Media Storage Service Class with the Interchange Option. (see PS3.4). SOP Classes and corresponding Transfer Syntaxes supported by the STD-CTMR-MOD12 Application Profiles is also specified in the Table 3.3.3.1.1-1. Table 3.3.3.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 The CT/MR Application Profiles in the STD-CTMR-MOD12 require the 130mm 1.2GB 512 Byte per Sector Magneto-Optical Rewritable physical media with the PC File System as defined in PS3.12. 3.3.3.1.3 Logical Format The STD-CTMR-MOD12 Application profile media format conforms to the Logical Format specification in PS3.12. The following table 3.3.3.1.3-1 defines the specific values used for this profile. Table 3.3.3.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 The modality attribute (0008,0060) in the DICOMDIR Series records should be CT/MR for Seconday Capture and Standalone Overlay SOP Class Images. Otherwise the SIGNA PROFILE DICOM media display browser will not list-up the series for contents rendering the retrieval to local storage impossible. 3.3.3.1.4.1 Additional Keys None. 3.3.3.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 The CT/MR Application Profiles in the STD-CTMR-MOD23 require the 130mm 1.2GB 512 Byte per Sector Magneto-Optical Rewritable physical media with the PC File System as defined in PS3.12. 3.3.3.2.3 Logical Format The STD-CTMR-MOD23 Application profile media format conforms to the Logical Format specification in PS3.12. The following table 3.3.3.2.3-1 defines the specific values used for this profile. Table 3.3.3.2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 The modality attribute (0008,0060) in the DICOMDIR Series records should be CT/MR for Secondary Capture and Standalone Overlay SOP Class Images. Otherwise the SIGNA PROFILE DICOM media display browser will not list-up the series for contents rendering the retrieval to local storage impossible. 3.3.3.2.4.1 Additional Keys None. 3.3.3.2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 decompression routine. See section 3.4.3 for details of the encoding problem unique to the PRI-CTMRMOD12 profile. 3.3.4.1.2 Physical Media and Media Formats The CT/MR Application Profiles in the PRI-CTMR-MOD12 require the 130mm 1.2GB 512 Byte per Sector Magneto-Optical Rewritable physical media with the PC File System as defined in PS3.12. 3.3.4.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 The attributes listed in Table 3.3.3.1.5.1-1 used within the CT/MR/SC/Standalone Overlay Image files, shall take the values specified. Overlay data if present shall be encoded in Overlay Data (60XX,3000). 3.3.4.1.5.1.1 Attribute Value Precedence None. 3.4 Extensions, Specialization’s and Privatization’s of SOP Classes and Transfer Syntaxes 3.4.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 3.6 Support of Extended Character Sets The MOD Archive Application will support copy of SOP instances containing the ISO IR 100 (Latin alphabet No. 1, supplementary set) and DICOM default character sets as defined in PS3.5. doc ver 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 4 PRINT SCU CONFORMANCE 4.0 Introduction This Conformance Statement (CS) specifies the SIGNA PROFILE compliance to DICOM v3.0. It details the DICOM Service Classes and roles which are supported by this product in it’s version 7.71. The SIGNA PROFILE product uses DICOM services to provide the DICOM Print SCU Application Profile. The SIGNA PROFILE product uses DICOM Print SCU to print images on DICOM Compliant Printers.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 4.1.2 Functional Definition of AE’s DICOM Print SCU Establishes the Association with requested printer to print the composed film. If the Remote AE accepts the presentation context applicable to the print job, the DICOM Print AE SCU will send the print job to the receiving Remote AE by using the NCREATE and N-SET services. 4.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 4.2.2 Association Establishment Policy 4.2.2.1 General The Print SCU provides options to indicate the printer AE title, Printer host name. In this product these inputs are provided by Film Composer. Depending on these inputs the Print SCU will establish the association with the desired printer. The DICOM Application Context Name (ACN), which is always proposed, is: Application Context Name 1.2.840.10008.3.1.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Print SCU initiates association with the Printer (which is running DICOM print SCP) provided as input to print SCU by film Composer. 4.2.3.1 Real World Activity 4.2.3.1.1 Associated Real-World Activity - “Print” The Film Composer allows the user to select printers and it also allows the user to drag and drop the images (from viewer application) into the film.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 4.2.3.1.3.1 Basic Film Session SOP Class The Print SCU supports the following DIMSE Service Elements for the Basic Film Session SOP Class. N-CREATE - Requests the Print SCP to create an instance of Basic Film Session.
GE Medical Systems REV 2.
GE Medical Systems REV 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 *Software Versions *Date Last Calibrated *Time Last Calibrated ( 1800, 1020 ) ( 1800, 1200 ) ( 1800, 1201 ) Printer shall return Value Printer shall return Value Printer shall return Value The Print SCU issues the N-GET service to retrieve the printer status. The statuses are processed as follows: • • • If Printer status (2110,0010) is NORMAL, the film is printed.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 4.4 Standard Extended/Specialised/Private SOPs None. 4.5 Configuration 4.5.1 AE Title/Presentation Address Mapping The Local AE title is "Print_SCU" . The SIGNA PROFILE system allows the user to “add”, “Remove”, or “Update” the mapping of remote DICOM Printer AE Titles to IP Addresses and Ports. These options can be selected from the “Remote Printer Selection” menu displayed by choosing “Configure” button from the Film Composer .
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Appendix A IDO Definitions Enclosed is a listing of only the Optional/Conditional modules/attributes used by this implementation for CT/MR/SC and Standalone Overlay IOD’s. NOTE: All other modules which are mandatory and consist of only type 1 elements and attributes which are type 1 pre DICOM standard are supported by this implementation but are not explicitly listed here. A.1 CT Specific IOD Definition A.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Defined Terms: SMOOTH SOFT STANDARD DETAIL BONE EDGE SHARP LUNG A.2 MR Specific IOD Definition A.2.1 MR Image IOD Modules Entity Name Module Name Patient Patient Study General Study Patient Study Series General Series Frame of Reference Frame of Reference Equipment General Equipment Image General Image Image Plane Image Pixel Contrast/Bolus MR Image SOP Common Reference A.5.1 A.5.2 A.5.3 A.5.4 A.5.12 A.5.5 A.5.6 A.5.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Trigger Window Reconstruction Diameter Receiving Coil Transmitting Coil Acquisition Matrix Phase Encoding Direction (0018,1094) (0018,1100) (0018,1250) (0018,1251) (0018,1310) (0018,1312) 3 3 3 3 3 3 Flip Angle Variable Flip Angle Flag (0018,1314) (0018,1315) 3 3 SAR Temporal Resolution (0018,1316) (0020,0110) 3 3 Sent if available, else not sent Always sent. (even if value is zero length) Sent if available, else not sent.
GE Medical Systems REV 2.7 Patient ID Patient’s Birth Date Patient’s Sex Referenced Patient Sequence >Referenced SOP Class UID >Referenced SOP Instance UID Patient’s Birth Time Other Patient IDs Other Patient Names Ethnic Group Patient Comments SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 (0010,0020) (0010,0030) (0010,0040) (0008,1120) (0008,1150) (0008,1155) (0010,0032) (0010,1000) (0010,1001) (0010,2160) (0010,4000) 2 2 2 3 1C 1C 3 3 3 3 3 A.5.
GE Medical Systems REV 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 the image. Older CT scanners used -32768 while newer scanners use -2000 as padding. A.5.
GE Medical Systems REV 2.7 Descriptor Red Palette Color Lookup Table Data Green Palette Color Lookup Table Data Blue Palette Color Lookup Table Data SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 (0028,1201) 1C Not Used. Discarded. (0028,1202) 1C Not Used. Discarded. (0028,1203) 1C Not Used. Discarded. A.5.
GE Medical Systems REV 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Attribute Name Overlay Number Tag (0020,0022) Type 2 Overlay Date Overlay Time (0008,0024) (0008,0034) 3 3 A.5.16 Requested Procedure Module Attribute Name Tag Requested Procedure ID (0040,1001) Referenced Study Sequence (0008,1110) >Referenced Study Sequence Class (0008,1150) UID >Referenced Study Sequence (0008,1155) Instance UID A.5.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Appendix B Private Data Elements Enclosed is a listing of private data elements used in this implementation for CT/MR Image IOD definition. B.1 CT Image IOD Private Data Elements Definition B.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Mid scan flag Degrees of azimuth Gantry period X-Ray On position X-Ray Off position Number of triggers Angle of first view Trigger frequency Scan FOV type Stat recon flag Compute type Segment number Total segments requested Interscan delay View compression factor Total no. of ref channels Data size for scan data Recon post proc. flag CT water number CT bone number Number of channels (1...
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Anatomical reference for scout Tube focal spot position Biopsy position Biopsy T location Biopsy ref location (0021,xx4A) (0021,xx90) (0021,xx91) (0021,xx92) (0021,xx93) LO SS SS FL FL 1 1 1 1 1 VR LO FD SL SS VM 1 1 1 1 VR LO SS SL SL SS SL SL SL SH VM 1 1 1 1 1 1 1 1 1 VR LO SL SS SL SS SL SL SS SH SS SH FL FL FL FL FL FL FL VM 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 B.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 R Coord of Top Right Corner A Coord of Top Right Corner S Coord of Top Right Corner R Coord of Bottom Right Corner A Coord of Bottom Right Corner S Coord of Bottom Right Corner Table start location Table end location RAS letter for side of image RAS letter for anterior/posterior RAS letter for scout starts loc. RAS letter for scout end loc.
GE Medical Systems REV 2.
GE Medical Systems REV 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 First scan ras First scan location Last scan ras Last scan loc. Display field of view Acquisition Duration Second echo Number of echoes Table delta Contiguous Peak SAR Monitor SAR Cardiac repetition time Images per cardiac cycle Actual receive gain analog Actual receive gain digital Delay after trigger Swappf Pause Interval Pulse Time Slice offset on freq.
GE Medical Systems REV 2.
GE Medical Systems REV 2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Number of images archived Last image number used Primary Receiver Suite and Host (0025,xx18) (0025,xx19) (0025,xx1A) SL SL SH 1 1 1 VR LO SL SS SH SS SS SL SS SL SH FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL VM 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 VR LO SL SL SL SL SL SS SL SL VM 1 1 1 1 1 1 1 1 1 B.2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 B.2.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 Appendix C DICOMDIR Directory Information C.1 DICOMDIR Directory Information Enclosed here is a listing of only the optional (conditional) modules and optional attributes used by this implementation in the DICOMDIR definition. All standard attributes as defined in Part 3 Addendum (Basic Directory Information Object) are supported by this implementation but not listed here. C.1.
GE Medical Systems REV 2.7 SIGNA PROFILE CONFORMANCE STATEMENT sm 2303347 C.1.3.3 Series Keys Attribute Name Specific Character Set Image Type Modality Manufacturer’s Id Series Description Manuf. Model Name Series Instance UID Series Number Tag (0008,0005) (0008,0008) (0008,0060) (0008,0070) (0008,103E) (0008,1090) (0020,000E) (0020,0011) Type 1C 3 1 3 3 3 1 1 Notes ISO_IR 100 C.1.3.