”LOG” “LOG” characteristic for CINEON DXR files.
black level 95
d
white level 685
d
highlight 1019
d
data output-code value
Lookup table input
LOG
1024
d
1024
d
0
d
Note!
This lookup table maps the image data to obtain a logarithmic transfer charac-
teristic from a linear signal without applying CRT Gamma.
This LUT is not recommended any more to be used on the Spirit DataCine as
it was replaced by the better suited C-PD lookup table.
”User Tab 01 - 15” Allows to use customer specified lookup tables.
To generate and perform a download of LUT to the
data output board of the Spirit DataCine see the
detailed description of the separate SDCMAINT
Manual FU 0058 provided in the supplement of this
manual