C-more 6” Micro-Graphic PLC Communication
Protocols & Cabling Chart
PLC Compatibility & Connection Chart
PLC
C-more
6” Micro-Graphic Panel
Family CPU
PLC Port &
Type
Panel to PLC Cabling Components Required for Specific Port and Protocol being used.
**PLC Port Powered or
External DC Power Supply
External DC Power Supply
Using panel’s RJ12 Port1
Using panel’s Port2
DB 15-pin - female
Protocol(s)
Supported
Components &
Network Type
Protocol(s)
Supported
Components &
Network Type
Direct
LOGIC
DL05
all versions
Port 1
RJ12 - 6 pin
K-sequence,
Direct
NET,
Modbus RTU
DV-1000CBL**
RS-232
K-sequence,
Direct
NET,
Modbus RTU
EA-2CBL
RS-232
Port 2
RJ12 - 6 pin
D0-DCM
Port 1
RJ12 - 6 pin
K-sequence,
Direct
NET,
Modbus RTU
DV-1000CBL**
RS-232
K-sequence,
Direct
NET,
Modbus RTU
EA-2CBL
RS-232
Port 2
DB15HD
(female)
DV-1000CBL**
+ FA-15HD
RS-232
EA-2CBL-1
RS-232
* See Note
RS-422
Modbus RTU
* See Note
RS-485
Modbus only
Direct
LOGIC
DL06
all versions
Port 1
RJ12 - 6 pin
K-sequence,
Direct
NET,
Modbus RTU
DV-1000CBL**
RS-232
K-sequence,
Direct
NET,
Modbus RTU
EA-2CBL
RS-232
Port 2
DB15HD
(female)
DV-1000CBL**
+ FA-15HD
RS-232
EA-2CBL-1
RS-232
* See Note
RS-422
Modbus RTU
* See Note
RS-485
Modbus only
D0-DCM
Port 1
RJ12 - 6 pin
K-sequence,
Direct NET,
Modbus RTU
DV-1000CBL**
RS-232
K-sequence,
Direct
NET,
Modbus RTU
EA-2CBL
RS-232
Port 2
DB15HD
(female)
DV-1000CBL**
+ FA-15HD
RS-232
EA-2CBL-1
RS-232
* See Note
RS-422
Modbus RTU
* See Note
RS-485
Modbus only
Direct
LOGIC
DL105
all versions
Port 1
RJ12 - 6 pin
K-sequence
DV-1000CBL**
RS-232
K-sequence
EA-2CBL
RS-232
Direct
LOGIC
DL205
D2-230
Port 1
RJ12 - 6 pin
K-sequence
DV-1000CBL**
RS-232
K-sequence
EA-2CBL
RS-232
D2-240
Port 1
RJ12 - 6 pin
K-sequence
DV-1000CBL**
RS-232
K-sequence
EA-2CBL
RS-232
Port 2
RJ12 - 6 pin
K-sequence,
Direct NET,
K-sequence,
Direct NET,
D2-250-1
D2-250-1
K-sequence,
Direct NET,
Modbus RTU
DV-1000CBL**
RS-232
K-sequence,
Direct
NET,
Modbus RTU
EA-2CBL
RS-232
Port 2
DB15HD
(female)
DV-1000CBL**
+ FA-15HD
RS-232
EA-2CBL-1
RS-232
* See Note
RS-422
D2-260
Port 1
RJ12 - 6 pin
K-sequence,
Direct
NET,
Modbus RTU
DV-1000CBL**
RS-232
K-sequence,
Direct
NET,
Modbus RTU
EA-2CBL
RS-232
Port 2
DB15HD
(female)
DV-1000CBL
+ FA-15HD
RS-232
EA-2CBL-1
RS-232
* See Note
RS-422
Modbus RTU
* See Note
RS-485
Modbus only
D2-DCM
Port 1
DB 25 pin
(female)
K-sequence,
Direct
NET,
Modbus RTU
See Note
RS-232
Direct
NET
EA-4CBL-2
RS-232
* See Note
RS-422
WINPLC
Port 1
RJ12 - 6 pin
Modbus RTU
DV-1000CBL**
RS-232
Modbus RTU
EA-2CBL
RS-232
* Note: See the
C-more
6” Micro-Graphic Hardware User Manual (P/N: EA1-MG6-USER-M), Chapter 6: PLC Communications, for wiring diagrams that
the user can use to construct their own cables. Available for download at www.automationdirect.com.
** Note: The PLC can provide 5 VDC through this cable. No external 12-24 VDC souce is required, however, screen brightness is diminished and the
alarm beep will not function. Low-Power Mode should be used during initial programming only. Connect an external 12-24 VDC power
source when the panel is installed in its application. PLC Compatibility & Connection Chart continued on next page.