Data Sheet
C-MAX Beacon BC08
Datasheet
SPEC No.
C-MAX Beacon
BC08 DataSheet
Revision
1.3
State
2019-12-17
Printed
2020-03-26
Version
English
Page
5 of 8
C-MAX
2.4 Battery Level Broadcast
An additional supplement advertisement packet will be broadcasted every 5 mins by default or
at an interval specified by the user within the range of 1 seconds and 3600 seconds. This
allows the mobile APP to check for the battery voltage and alert for battery low conditions.
2.5 Beacon Settings Customization
If the Beacon is configured as “ENABLE PROGRAMMING”, the user can customise his own
beacon parameters including the following:
- Programmable UUID
o 16 bytes, each byte ranging from 0x00 to 0xFF
o Default set = E2C56DB5-DFFB-48D2-B060-D0F5A71096E0
- Programmable Major ID
o Range from 0x0001 to 0xFFFF
o Default set = 10000
- Programmable Minor ID
o Range from 0x0001 to 0xFFFF
o Default set = 10
- Programmable Advertising Interval
o Input range from 600 milliseconds to 10000 milliseconds
- Battery Level Broadcast Interval
o Input range from 1 second to 3600 seconds
o Default set = 300 seconds (that is, 5 minutes)
- Programmable Measured Power at 1 meter
o 2’s complement of the calibrated TxPower, from 0x00 to 0xFF
o Default set = 0xC5 = -59dBm
3. Electrical Characteristics
Specification
Min
Typ
Max
Units
Condition
Operating Voltage
2.6
3.0
3.3
Lithium Coin cell CR2032
battery, 25 °C , 50% humidity
Battery Lifetime
(Before Activation)
50
months
CR2032 battery with 220 mAh
@ 80% capacity
Battery Lifetime
(After Activation)
18
months
CR2032 battery with 220 mAh
@ 80% capacity, Beacon