Operating instructions

Planning
Please ensure that you are familiar with the installation
requirements as well as the relevant British Standards and
Statutory Regulations (see page 3) before commencing work.
Location
The CALYDRA can be installed on any suitable internal wall.
Provision must be made to allow the correct routing of the flue
and siting of the terminal to allow the safe and efficient
removal of the flue products. The appliance may be installed
in any room, although reference must be made to the IEE
regulations if it contains a bath or shower. A compartment or
cupboard may be used provided that it has been purpose-built
or modified for the purpose. It is not necessary to provide
permanent ventilation for cooling purposes. Detailed
recommendations are given in BS 5440 pt 2. If it is proposed
that it is installed in a timber framed building then reference
must be made to British Gas Document DM2, or advice
sought from CORGI.
INSTALLING THE CALYDRA
Installation
The installation kit included with the flue components
comprise following items :
- Hanging bracket
- A paper template (showing the dimensions of the boiler with
5 mm side clearances and fitting instructions and on the
reverse, the fixing positions for the spacer bracket)
- Connection tails
- Screws and wall plugs
- Connection washers
- Pre-piping jig
- Installation and Operation manual
Positioning the boiler on the wall.
The paper template can be used to ensure the correct
positioning of kitchen cabinets etc.
The paper template is fixed to the wall and used to locate the
position of the hanging bracket, the centre for the flue hole
and, if required, the fixings for the pre-piping jig.
If there is a requirement to pass the piping behind the
boiler, it will be necessary to fit a spacing bracket. This is
available as an optional accessory. The standard paper
template shows the positions for the spacing bracket
fixing screws.
q
chaffoteaux~
a-u