Installation & Assembly

1
Installation Instructions for
Secure the mounting plate to the junction box.
Connect the fixture ground wire to a suitable ground in accordance to local electrical codes.
Connect the white fixture wire to the neutral power line wire with a wire nut.
Connect the black fixture wire to the hot power line wire with a wire nut.
Properly place all wires and wire nut connections into the junction box/fixture base, mount the fixture onto the mounting plate,
and secure it in place using the fixture screws.
Install the candle tube(s) by sliding over the socket(s).
For Model CW1032 Only: Place shade onto candle tubes through bottom opening of shade, install counter rings over shade
washers onto threaded sockets until shade is secure.
Screw the lamp(s) into the socket(s). Refer to the label on the socket for Max Wattage Information.
For Model CW1031 Only: Install the shade by placing it over the lamp.
1
2
3
4
5
Westerly Wall
1.1
CW1031-CW1032
CW1031,CW1032
6
1A
7
Wall
CAUTION RISK OF FIRE-
This product must be installed in accordance with the
applicable installation code by a person familiar with the
construction and operation of the product and the hazards
involved.
Use minimum 90°c supply conductors.
GP I :ENERAL RODUCT NFORMATION
These fixtures are intended to be installed utilizing NEC compliant junction
boxes.
This product is safety listed for damp locations.
Incandescent lamps may be dimmed with a standard incandescent dimmer.
LED lamps may be dimmed with a LED dimmer. Consult lamp manufacturer
for additional information.
JUNCTION BOX
MOUNTING PLATE
3
4
SHADE
FIXTURE SCREW
5
8
LAMP
CANDLE TUBE
SOCKET
6
9
8
9
COUNTER RING
(MODEL CW1032 ONLY)
7
THREADED SOCKET
LAMP
CANDLE TUBE
SHADE
8
6
MODEL CW1032