Installation manual
SYSTEM 236 Installation Manual
14
CL 12 - 14
Command Locations 12 - 14: RPS Phone Number
Order in which the numbers will be dialed
Command Location 12
(1) (2) (3) (4) (5) (6)
Command Location 13
(1) (2) (3) (4) (5) (6)
Command Location 14
(1) (2) (3) (4) (5) (6)
Command Location 12: RPS Phone Number (digits 1 - 6)
12
E00000
(1) (2) (3) (4) (5) (6)
Default Values
#
Digit Positions (1) - (6): RPS Phone Number (Digits 1 - 6)
0 - 9 = dialing digits
0 = dial tone detect (use if more than one dial tone must be detected)
2 = * (DTMF dialing only, not used in pulse dialing)
3 = # (DTMF dialing only, not used in pulse dialing)
4 = end of number
5 = 5 second delay
Digit (1) is dialed first.
You must place a 4 (EON) after the last digit to be dialed.
Fill in remaining Positions with "0". Zeroes after EON will
not be dialed.
Command Location 13: RPS Phone Number (digits 7 - 12)
13
000000
(1) (2) (3) (4) (5) (6)
Default Values
Command Location 14: RPS Phone Number (digits 13 - 18)
14
000000
(1) (2) (3) (4) (5) (6)
Default Values
#
#
PROGRAMMING CONVERSIONS
Hexadecimal Value
Key Strokes
A
B
C
D
E
F
0
1
2
3
4
5
NOTE: Some Alpha keypads may have a [SHIFT] key
and an [ENTER] key in place of the [*] and [#]
keys, respectively. This manual uses the [*] for the
[SHIFT] key and the [#] for the [ENTER] key.