Installation manual
4
SPECIFICATIONS
The following information explains the specifications of the panel.
SPECIFICATION FOR SOFTWARE REVISION NUMBER V2.0
The software revision number is located on the top of the main processor.
SPECIFICATION
Power Supply
Mains Supply Voltage 230 V AC Nominal
PSU output voltage 13.7 V Nominal
Maximum output current 1 A (total)
Aux. current 500 mA Max.
Battery Fuse 1 A (20 mm)
Panel Quiescent 40 mA
Keypads
Supply Voltage 13.7 V
Quiescent Current 20 mA
Active 45 mA
Maximum number allowed 6
General For internal use only
Normal operating temperature 0°C to 40°C
Humidity 10 to 90% R.H. non condensing
Dimensions 263 mm (W) 223 mm (H) 82 mm (D)
Control Panel Weight 2.7 kg Excluding Battery
Stand by Battery 7.0Ahr max. valnve regulated lead acid
Standby Time (load dependent) 24 hrs with 2.8Ahr nom.
60 hrs with 7.0Ahr nom. based on
(
panel+keypad+2*PIR=40+20+25+25mA
)
Cable run per zone/circuit 100m max with 50mA load
Cable run (alarm sounder) 50m max with 7/0.2 cable
100 max with 16/0.2 or 7/0.2 paralleled
Factory Defaults
User/customer Code 1 1234
User/customer Code 2 Disabled (0000)
Engineer Code 7890
Circuit 1 Entry Circuit. (Fixed)
Circuit 2 Alarm Circuit isolated in Night set.
Circuit 3 Alarm Circuit.
Circuit 4 Alarm Circuit.
Circuit 5 Alarm Circuit.
Circuit 6 Alarm Circuit.
Circuit 7 Alarm Circuit.
Circuit 8 P.A (Personal Attack)
Full Set Exit Time 30 Seconds
Night set Exit Time 15 Seconds
Entry time 30 Seconds
Sounder Ring Time 15 Minutes
Chimes Disabled
PROCESSOR
VERSION
POWER
SUPPLY
KEYPADS
GENERAL
FACTORY