Instruction Manual

Document Number: 94634 For technical questions, contact: indmodules@vishay.com
www.vishay.com
Revision: 09-Mar-11 3
This datasheet is subject to change without notice.
THE PRODUCT DESCRIBED HEREIN AND THIS DATASHEET ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
VSKCS400/045
ADD-A-PAK Generation VII
Power Modules Schottky Rectifier, 400 A
Vishay Semiconductors
Fig. 1 - Maximum Forward Voltage Drop Characteristics
Fig. 2 - Typical Values of Reverse Current vs.
Reverse Voltage
Fig. 3 - Typical Junction Capacitance vs.
Reverse Voltage
Fig. 4 - Maximum Thermal Impedance Z
thJC
Characteristics
Forward Voltage Drop - V
FM
(V)
Instantaneous Forward Current - I
F
(A)
0.0 0.3 0.6 0.9 1.2 1.5
1
10
100
1000
Tj = 25°C
Tj = 125°C
Tj = 150°C
Reverse Current - I
R
(mA)
Reverse Voltage - V
R
(V)
0 1020304050
0.1
1
10
100
1000
10000
25°C
75°C
100°C
50°C
125°C
150°C
Reverse Voltage - V
R
(V)
Junction Capacitance - C
T
(pF)
1000
10000
0 1020304050
T = 2 5 ° C
J
t1, Rectangular Pulse Duration (Seconds)
Thermal Impedance ZthJC (°C/W)
1E-05 1E-04 1E-03 1E-02 1E-01 1E+00 1E+01 1E+02
0.001
0.01
0.1
1
Single Pulse
(Thermal Resistance)
D = 0.2
D = 0.25
D = 0.33
D = 0.5
D = 0.75