Owner's manual

VS-HFA220FA120
www.vishay.com
Vishay Semiconductors
Revision: 22-Mar-12
2
Document Number: 93636
For technical questions within your region: DiodesAmericas@vishay.com
, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 1 - Typical Forward Voltage Drop Characteristics (Per Leg) Fig. 2 - Typical Values of Reverse Current vs. Reverse Voltage
DYNAMIC RECOVERY CHARACTERISTICS (T
J
= 25 °C unless otherwise specified)
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Reverse recovery time t
rr
T
J
= 25 °C
I
F
= 1 A
dI
F
/dt = - 200 A/μs
V
R
= 30 V
-58-
ns
T
J
= 25 °C
I
F
= 50 A
dI
F
/dt = - 200 A/μs
V
R
= 200 V
-157-
T
J
= 125 °C - 255 -
Peak recovery current I
RRM
T
J
= 25 °C - 15 -
A
T
J
= 125 °C - 22.5 -
Reverse recovery charge Q
rr
T
J
= 25 °C - 1150 -
nC
T
J
= 125 °C - 2850 -
Junction capacitance C
T
V
R
= 1200 V - 53 - pF
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Junction to case, single leg conducting
R
thJC
--0.25
°C/WJunction to case, both legs conducting - - 0.125
Case to heatsink R
thCS
Flat, greased and surface - 0.10 -
Weight -30- g
Mounting torque -1.3-Nm
1
10
100
1000
0.5 1 1.5 2 2.5 3 3.5 4
I
F
- Instantaneous Forward Current (A)
V
F
- Forward Voltage Drop (V)
T
J
= 150 °C
T
J
= 125 °C
T
J
= 25 °C
0.0001
0.001
0.01
0.1
1
10
0 200 400 600 800 1000 1200
I
R
- Reverse Current (μA)
V
R
- Reverse Voltage (V)
T
J
= 150 °C
T
J
= 125 °C
T
J
= 25 °C