User guide

TDK4_ _3002
Phase Control Thyristo
r
Powerex, Inc., 173 Pavilion Ln, Youngwood, PA 15697-1800 (724)925-7272 www.pwrx.com 3070 Amperes 4500 Volts
Absolute Maximum Ratings
Characteristic Symbol Rating Units
Repetitive Peak Voltage
V
DRM
-V
RRM
4000 - 4500 Volts
Average On-State Current, T
C
=70°C
I
T(Avg.)
3070 A
RMS On-State Current, T
C
=70°C
I
T(RMS)
4822 A
Average On-State Current, T
C
=55°C
I
T(Avg.)
3430 A
RMS On-State Current, T
C
=55°C
I
T(RMS)
5388 A
Peak One Cycle Surge Current, 60Hz, V
R
=0V I
TSM
56,000 A
Peak One Cycle Surge Current, 50Hz, V
R
=0V I
TSM
52,797 A
Fuse Coordination I
2
t, 60Hz I
2
t
1.31E+07
A
2
s
Fuse Coordination I
2
t, 50Hz I
2
t
1.39E+07
A
2
s
Critical Rate-of-Rise of On-State Current di/dt 100 A/us
Repetitive from .67•VDRM
Critical Rate-of-Rise of On-State Current di/dt 150 A/us
Non-Repetitive from .67•VDRM
Peak Gate Power, 100us
P
GM
16 Watts
Average Gate Power
P
G(avg)
5 Watts
Operating Temperature Tj -40 to+125 °C
Storage Temperature
T
Stg.
-40 to+150 °C
Approximate Weight 6.5 lb
2.95 Kg
Mounting Force 18,000 - 25,000 lbs
80 - 110 KNewtons
Ratings apply for operation at rated load force.
Information presented is based upon manufacturers testing and
projected capabilities. This information is subject to change
without notice. The manufacturer makes no claim as to suitability
for use, reliability, capability or future availability of this product.
Page 2