Note
The table above shows the increment of thermal resistance R
thJC
when devices operate at different conduction angles than DC
Fig. 1 - Current Ratings Characteristics Fig. 2 - Current Ratings Characteristics
Fig. 3 - On-State Power Loss Characteristics
ΔR
thJC
CONDUCTION
CONDUCTION ANGLE SINUSOIDAL CONDUCTION RECTANGULAR CONDUCTION TEST CONDITIONS UNITS
180° 0.034 0.025
T
J
= T
J
maximum K/W
120° 0.040 0.042
90° 0.052 0.056
60° 0.076 0.079
30° 0.126 0.127
110
100
90
80
130
030
60
90
Maximum Allowable Case
Temperature (°C)
Average On-State Current (A)
10 40 7020 50 80
120
60°30° 90° 120° 180°
100 110
ST103S Series
R
thJC
(DC) = 0.195 K/W
Ø
Conduction angle
060
120
180
Maximum Allowable Case
Temperature (°C)
Average On-State Current (A)
20 80 14040 100 160
30° 60° 90° 120° 180°
110
100
90
70
130
120
80
Ø
Conduction period
DC
ST103S Series
R
thJC
(DC) = 0.195 K/W
0
20
40
60
80
100
120
140
160
180
Maximum Average On-State
Power Loss (W)
Average On-State Current (A)
030
60
90
10 40 7020 50 80
100 110
180°
120°
90°
60°
30°
RMS limit
Conduction angle
ST083S Series
T
J
= 125 °C
Ø
0
20
40
60
80
100
120
140
160
180
Maximum Average On-state
Power Loss (W)
25 50 75 100 125
Maximum Allowable Ambient Temperature (°C)
0.2 K/W
R
thSA
= 0.1 K/W - ΔR
0.3 K/W
0.4 K/W
0.5 K/W
0.8 K/W
1.2 K/W