User guide

MITSUBISHI ELECTRIC CORPORATION
HIGH VOLTAGE DIODE MODULE
HVM-2006-A
(HV-SETSU)
PAGE
2 / 11
6. Maximum Ratings
Item Symbol Conditions Ratings Unit
6.1 Repetitive peak reverse voltage V
RRM
T
j
= 25 °C 4500 V
6.2 Non-repetitive peak reverse
voltage
V
RSM
T
j
= 25 °C 4500 V
6.3 Reverse DC voltage V
R(DC)
T
j
= 25 °C 3000 V
6.4 DC forward current I
F
T
c
= 25 °C 600 A
6.5 Surge forward current I
FSM
T
j
= 25 °C start, t
w
= 8.3 ms
Half sign wave
4800 A
6.6 Surge current load integral I
2
t
T
j
= 25 °C start, t
w
= 8.3 ms
Half sign wave
95.6 kA
2
s
6.7 Isolation voltage V
iso
Charged part to the baseplate
RMS sinusoidal, 60Hz 1min.
6000 V
6.8 Junction temperature T
j
40 ~ +150 °C
6.9 Storage temperature T
stg
40 ~ +125 °C
6.10 Operating temperature T
op
40 ~ +125 °C
6.11 Maximum reverse recovery
instantaneous power
V
R
3000 V
di/dt 2000 A/µs, T
j
= 125 °C
[See Fig.1, Fig.2, 12-5]
600 kW
7. Electrical Characteristics
Limits
Item Symbol Conditions
Min. Typ. Max.
Unit
T
j
= 25 °C
— — 5
7.1 Repetitive reverse current I
RRM
V
RM
= V
RRM
T
j
= 125 °C
— — 30
mA
T
j
= 25 °C
— 4.80
7.2 Forward voltage V
FM
(Note 1)
I
F
= 600 A
T
j
= 125 °C
— 4.20
V
7.3 Reverse recovery time t
rr
0.90 1.8 µs
7.4 Reverse recovery charge Q
rr
600 µC
7.5 Reverse recovery energy E
rec
V
R
= 2250 V, I
F
= 600 A
di/dt = 1400 A/µs
T
j
= 125 °C
[See Fig.1,Fig.2]
— 0.62 J/P