User guide

PS51789
Intellimod™ Module
Dual-In-Line Intelligent Power Factor Correction Module
30 Amperes/600 Volts
2 03/10 Rev. 0
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com
Absolute Maximum Ratings, T
j
= 25°C unless otherwise specified
Characteristics Symbol PS51789 Units
Input Supply Voltage (Between S-R Terminals) V
i
264 V
rms
Input Supply Voltage, Surge (Between S-R Terminals) V
i(surge)
500 Volts
Output Voltage (Between P-N Terminals) V
O
450 Volts
Output Voltage, Surge (Between P-N Terminals) V
O(surge)
500 Volts
Collector-Emitter Voltage V
CES
600 Volts
Repetative Peak Reverse Voltage V
RRM
600 Volts
Input Current, 100% Load (T
C
≤ 100°C, V
i
= 220V
rms
, V
O
= 390V, f
PWM
= 20kHz) I
i
30 A
rms
Input Current, 125% Load (T
C
≤ 100°C, V
i
= 220V
rms
, V
O
= 390V, I
i(125%)
37.5 A
rms
f
PWM
= 20kHz, Non-repetative, within 1 Minute)
I
2
t for Fusing (Value for 1 Cycle of Surge Current, tw = 8.3ms) I
2
t 270 A
2
s
Junction Temperature* T
j
-20 to 150 °C
Module Case Operation Temperature T
C
-20 to 100 °C
Storage Temperature T
stg
-40 to 125 °C
Mounting Torque, M3 Mounting Screws 8.7 in-lb
Module Weight (Typical) 21 Grams
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal, Connection Pins to Heatsink Plate V
ISO
2500 V
rms
Control Sector
Control Supply Voltage (Applied between V
D
-GND) V
D
20 Volts
Input Voltage (Applied between V
IN
-GND) V
IN
0 ~ V
D
+0.5 Volts
Fault Output Supply Voltage (Applied between F
O
-V
NC
) V
FO
-0.5 ~ V
D
+0.5 Volts
Fault Output Current (Sink Current at F
O
Terminal) I
FO
1 mA
Current Sensing Input Voltage (Applied between C
IN
-V
NC
) V
SC
-0.5 ~ V
D
+0.5 Volts
*The maximum junction temperature rating of the power chips integrated within the DIPPFC is 150°C (@T
C
100°C). However, to ensure safe operation of the DIPPFC,
the average junction temperature should be limited to T
j(avg)
125°C (@T
C
100°C).
T
C
Measurement Point
4.6 mm
25.4mm
IGBT
CONTROL TERMINALS
POWER TERMINALS
T
C
POINT