6121 Baker Road, Suite 108 Minnetonka, MN 55345 Phone (952) 933-6190 Fax (952) 933-6223 1-800-274-4284 www.chtechnology.com Thank you for downloading this document from C&H Technology, Inc. Please contact the C&H Technology team for the following questions - Technical Application Assembly Availability Pricing Phone – 1-800-274-4284 E-Mail – sales@chtechnology.com www.chtechnology.com - SPECIALISTS IN POWER ELECTRONIC COMPONENTS AND ASSEMBLIES - www.chtechnology.
PS22056 Powerex, Inc., 200 E.
Powerex, Inc., 200 E.
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PS22056 Intellimod™ Module Dual-In-Line Intelligent Power Module 25 Amperes/1200 Volts Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units IGBT Inverter Sector Collector-Emitter Saturation Voltage Diode Forward Voltage VCE(sat) VEC Inductive Load Switching Times IC = 25A, Tj = 25°C, VD = VDB = 15V, VIN = 5V — 2.7 3.
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PS22056 Intellimod™ Module Dual-In-Line Intelligent Power Module 25 Amperes/1200 Volts Thermal Characteristics Characteristic Symbol Condition Min. Typ. Max. Units Junction to Case Rth(j-c)Q IGBT Part (Per 1/6 Module) — — 1.28 °C/Watt Thermal Resistance Rth(j-c)D FWDi Part (Per 1/6 Module) — — 1.70 °C/Watt Contact Thermal resistance Rth(c-f) Per 1 Module — — 0.047 °C/Watt Min. Typ.
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PS22056 Intellimod™ Module Dual-In-Line Intelligent Power Module 25 Amperes/1200 Volts Application Circuit +5V +15V RSF CSF 21 R3 28 WN VN FAULT LOGIC VNC C2 VN1 +VCC WP VP VP1 C2 C2 C1 D1 C1 U VP1 C2 AC LINE C6 C7 C6 P + + VUFB + R1 VVFS UP C5 R2 MOTOR V VVFB + R1 W GATE DRIVE UV PROT. D1 HVIC C5 +VCC R2 C2 HVIC C1 This symbol indicates connection to ground plane.
Powerex, Inc., 200 E.
Powerex, Inc., 200 E.
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PS22056 Intellimod™ Module Dual-In-Line Intelligent Power Module 25 Amperes/1200 Volts COLLECTOR-EMITTER SATURATION VOLTAGE CHARACTERISTICS (TYPICAL - INVERTER PART) OUTPUT CHARACTERISTICS (TYPICAL - INVERTER PART) VD = 16.5V 20 13.5 15 10 5 2.0 2.5 1.0 VD = VDB = 15V Tj = 25°C Tj = 125°C 0.5 0 6 12 18 24 2.2 IC = 15A 1.8 1.0 13 30 Tj = 25°C Tj = 125°C IC = 5A 1.
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PS22056 Intellimod™ Module Dual-In-Line Intelligent Power Module 25 Amperes/1200 Volts 4 VCC = 600V VCIN = 0 ⇔ 5V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD 3 SWITCHING LOSS, PSW(on), (mJ/PULSE) 2 1 0 6 12 18 24 0 6 12 18 24 1 0 30 0 6 12 18 24 SWITCHING TIME (ON) VS. COLLECTOR CURRENT (TYPICAL - INVERTER PART N-SIDE) SWITCHING TIME (OFF) VS.
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PS22056 Intellimod™ Module Dual-In-Line Intelligent Power Module 25 Amperes/1200 Volts SWITCHING TIME (ON) VS. COLLECTOR CURRENT (TYPICAL - INVERTER PART P-SIDE) SWITCHING TIME (OFF) VS.