Owner's manual
PS22052
Intellimod™ Module
Dual-In-Line Intelligent Power Module
5 Amperes/1200 Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
3Rev. 10/05
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage V
CE(sat)
I
C
= 5A, T
j
= 25°C, V
D
= V
DB
= 15V, V
IN
= 5V — 2.7 3.4 Volts
I
C
= 5A, T
j
= 125°C, V
D
= V
DB
= 15V, V
IN
= 5V — 2.5 3.2 Volts
Diode Forward Voltage V
EC
-I
C
= 5A, V
IN
= 0V — 2.4 2.9 Volts
Inductive Load Switching Times t
on
0.8 1.5 2.2 µs
t
rr
V
CC
= 600V, V
D
= V
DB
= 15V, — 0.2 — µs
t
C(on)
I
C
= 5A, T
j
= 125°C, V
IN
= 0 ⇔ 5V, — 0.4 0.7 µs
t
off
Inductive Load (Upper-Lower Arm) — 2.8 3.8 µs
t
C(off)
— 0.4 0.7 µs
Collector-Emitter Cutoff Current I
CES
V
CE
= V
CES
, T
j
= 25°C — — 1.0 mA
V
CE
= V
CES
, T
j
= 125°C — — 10 mA
Control Sector
Circuit Current I
D
V
IN
= 5V Total of V
P1
-V
PC
, V
N1
-V
NC
— — 3.70 mA
V
D
= V
DB
= 15V V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
— — 1.30 mA
V
IN
= 0V Total of V
P1
-V
PC
, V
N1
-V
NC
— — 3.50 mA
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
— — 1.30 mA
Fault Output Voltage V
FOH
V
SC
= 0V, F
O
Terminal Pull-up to 5V by 10kΩ 4.9 — — Volts
V
FOL
V
SC
= 1V, I
FO
= 1mA — — 1.10 Volts
Input Current I
IN
V
IN
= 5V 0.70 1.5 2.00 mA
Short Circuit Trip Level* V
SC(ref)
V
D
= 15V 0.43 0.48 0.53 Volts
Supply Circuit Under-voltage UV
DBt
Trip Level, T
j
≤ 125°C 10.0 — 12.0 Volts
UV
DBr
Reset Level, T
j
≤ 125°C 10.5 — 12.5 Volts
UV
Dt
Trip Level, T
j
≤ 125°C 10.3 — 12.5 Volts
UV
Dr
Reset Level, T
j
≤ 125°C 10.8 — 13.0 Volts
Fault Output Pulse Width** t
FO
C
FO
= 22nF 1.6 2.4 — ms
ON Threshold Voltage V
th(on)
Applied between U
P
, V
P
, W
P
-V
PC,
2.5 3.0 4.2 Volts
OFF Threshold Voltage V
th(off)
U
N
, V
N
, W
N
-V
NC
0.8 1.4 2.0 Volts
* Short Circuit protection is functioning only for N-side IGBTs. Please select the value of the external shunt resistance such that the SC trip level is less than 1.7 times the current rating.
**Fault output is asserted when the lower arms short circuit or control supply under-voltage protection function operates. The fault output pulse-width t
FO
depends on the capacitance value
of C
FO
according to the following approximate equation: C
FO
= (9.3 x 10
-6
) x t
FO
{F} .