User Manual
PS21997-4, PS21997-4A
Intellimod™ Module
Dual In-line Intelligent Power Module
30 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
310/09
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specied
Characteristics Symbol Test Conditions Min. Typ. Max. Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage V
CE(sat)
V
D
= V
DB
= 15V, I
C
= 30A, V
IN
= 5V, T
j
= 25°C — 1.90 2.50 Volts
V
D
= V
DB
= 15V, I
C
= 30A, V
IN
= 5V, T
j
= 125°C — 2.00 2.60 Volts
Diode Forward Voltage V
EC
T
j
= 25°C, -I
C
= 30A, V
IN
= 0V — 1.70 2.20 Volts
Switching Times t
on
V
CC
= 300V, 0.70 1.30 1.90 µs
t
rr
V
D
= V
DB
= 15V, — 0.30 — µs
t
C(on)
I
C
= 30A, T
j
= 125°C, — 0.40 0.60 µs
t
off
V
IN
= 0 ⇔ 5V, — 1.70 2.65 µs
t
C(off)
Inductive Load (Upper and Lower Arm) — 0.40 1.00 µs
Collector-Emitter Cutoff Current I
CES
V
CE
= V
CES
, T
j
= 25°C — — 1.0 mA
V
CE
= V
CES
, T
j
= 125°C — — 10 mA
Control Sector
Circuit Current I
D
V
IN
= 5V Total of V
P1
-V
NC
, V
N1
-V
NC
— — 2.80 mA
V
D
= V
DB
= 15V V
UFB
-U, V
VFB
-V, V
WFB
-W — — 0.55 mA
V
IN
= 0V Total of V
P1
-V
NC
, V
N1
-V
NC
— — 2.80 mA
V
UFB
-U, V
VFB
-V, V
WFB
-W — — 0.55 mA
Fault Output Voltage V
FOH
V
SC
= 0V, F
O
Terminal Pull-up to 5V by 10kΩ 4.9 — — Volts
V
FOL
V
SC
= 1V, I
FO
= 1mA — — 0.95 Volts
Short Circuit Trip Level* V
SC(ref)
V
D
= 15V 0.43 0.48 0.53 Volts
Input Current I
IN
V
IN
= 5V 0.70 1.00 1.50 mA
Supply Circuit Under-voltage UV
DBt
Trip Level, T
j
≤ 125°C 10.0 — 12.0 Volts
Protection UV
DBr
Reset Level, T
j
≤ 125°C 10.5 — 12.5 Volts
UV
Dt
Trip Level, T
j
≤ 125°C 10.3 — 12.5 Volts
UV
Dr
Reset Level, T
j
≤ 125°C 10.8 — 13.0 Volts
Fault Output Pulse Width** t
FO
40 — — µs
ON Threshold Voltage V
th(on)
Applied between — 2.1 2.6 Volts
OFF Threshold Voltage V
th(off)
U
P
, V
P
, W
P,
0.8 1.3 — Volts
ON/OFF Threshold Hysteresis Voltage V
th(hys)
U
N
, V
N
, W
N
-V
NC
0.35 0.65 — Volts
* Short Circuit protection is functioning only for the low-arms. Please select the value of the external shunt resistor such that the S
C
trip level is less than 1.7 times the current rating.
**Fault signal is asserted only for a U
V
or S
C
condition on the low side. On a S
C
fault the F
O
duration will be 40µsec. On a U
V
condition the fault signal will be asserted as long as the
U