Instruction Manual

PS21964-4S
Intellimod™ Module
Dual-In-Line Intelligent Power Module
15 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
3Rev. 12/09
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specied
Characteristics Symbol Test Conditions Min. Typ. Max. Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage V
CE(sat)
V
D
= V
DB
= 15V, I
C
= 15A, V
IN
= 5V, T
j
= 25°C 1.70 2.20 Volts
V
D
= V
DB
= 15V, I
C
= 15A, V
IN
= 5V, T
j
= 125°C 1.80 2.30 Volts
Diode Forward Voltage V
EC
-I
C
= 15A, V
IN
= 0V 1.70 2.20 Volts
Inductive Load Switching Times t
on
0.70 1.30 1.90 µs
t
rr
V
CC
= 300V, V
D
= V
DB
= 15V, 0.30 µs
t
C(on)
I
C
= 15A, T
j
= 125°C, 0.50 0.75 µs
t
off
V
IN
= 0 5V, Inductive Load, 1.60 2.20 µs
t
C(off)
0.50 0.80 µs
Collector Cutoff Current I
CES
V
CE
= V
CES
, T
j
= 25°C 1.0 mA
V
CE
= V
CES
, T
j
= 125°C 10 mA
Control Sector
Circuit Current I
D
V
IN
= 5V Total of V
P1
-V
NC
, V
N1
-V
NC
2.80 mA
V
D
= V
DB
= 15V V
UFB
-U, V
VFB
-V, V
WFB
-W 0.55 mA
V
IN
= 0V Total of V
P1
-V
NC
, V
N1
-V
NC
2.80 mA
V
UFB
-U, V
VFB
-V, V
WFB
-W 0.55 mA
Fault Output Voltage V
FOH
V
SC
= 0V, F
O
Terminal Pull-up to 5V by 10kΩ 4.9 Volts
V
FOL
V
SC
= 1V, I
FO
= 1mA 0.95 Volts
Input Current I
IN
V
IN
= 5V 0.70 1.00 1.50 mA
Short Circuit Trip Level* V
SC(ref)
V
D
= 15V* 0.43 0.48 0.53 Volts
Supply Circuit Under-voltage UV
DBt
Trip Level, T
j
125°C 10.0 12.0 Volts
UV
DBr
Reset Level, T
j
125°C 10.5 12.5 Volts
UV
Dt
Trip Level, T
j
125°C 10.3 12.5 Volts
UV
Dr
Reset Level, T
j
125°C 10.8 13.0 Volts
Fault Output Pulse Width** t
FO
20 µs
ON Threshold Voltage V
th(on)
Applied between 2.1 2.6 Volts
OFF Threshold Voltage V
th(off)
U
P
, V
P
, W
P
-V
NC,
0.8 1.3 Volts
ON/OFF Threshold Hysteresis Voltage V
th(hys)
U
N
, V
N
, W
N
-V
NC
0.35 0.65 Volts
* Short Circuit protection is functioning only for the low-arms. Please select the value of the external shunt resistor such that the S
C
trip level is less than 1.7 times the current rating.
**Fault signal is asserted only for a U
V
or S
C
condition on the low side. On a S
C
fault the F
O
duration will be 20µsec. On a U
V
condition the fault signal will be asserted as long as the
U
V
condition exists or for 20µsec, whichever is longer.