Manual

PS21963-4, PS21963-4A, PS21963-4C
Intellimod™ Module
Dual-In-Line Intelligent Power Module
10 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
4 Rev. 12/09
Thermal Characteristics
Characteristic Symbol Condition Min. Typ. Max. Units
Junction to Case R
th(j-c)Q
Inverter IGBT (Per 1/6 Module) 3.7 °C/Watt
R
th(j-c)D
Inverter FWDi (Per 1/6 Module) 4.5 °C/Watt
Recommended Conditions for Use
Characteristic Symbol Condition Min. Typ. Value Units
Supply Voltage V
CC
Applied between P-N Terminals 0 300 400 Volts
Control Supply Voltage V
D
Applied between V
P1
-V
NC
, V
N1
-V
NC
13.5 15.0 16.5 Volts
V
DB
Applied between V
UFB
-U,
13.0 15.0 18.5 Volts
V
VFB
-V, V
WFB
-W
Control Supply Variation
dV
D
, dV
DB
-1 1 V/µs
Arm Shoot-through Blocking Time t
DEAD
For Each Input Signal, T
C
100°C 1.5 µs
Allowable Minimum Input P
WIN(on)
0.5 µs
Pulse Width* P
WIN(off)
0.5 µs
V
NC
Voltage Variation V
NC
Between V
NC
-N (Including Surge) -5.0 5.0 Volts
*DIP-IPM might not make response or work properly if the input signal plus width is less than the recommended minimum value.