6121 Baker Road, Suite 108 Minnetonka, MN 55345 Phone (952) 933-6190 Fax (952) 933-6223 1-800-274-4284 www.chtechnology.com Thank you for downloading this document from C&H Technology, Inc. Please contact the C&H Technology team for the following questions - Technical Application Assembly Availability Pricing Phone – 1-800-274-4284 E-Mail – sales@chtechnology.com www.chtechnology.com - SPECIALISTS IN POWER ELECTRONIC COMPONENTS AND ASSEMBLIES - www.chtechnology.
PS21767 Powerex, Inc.
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 PS21767 Intellimod™ Module Dual-In-Line Intelligent Power Module 30 Amperes/600 Volts Absolute Maximum Ratings, Tj = 25°C unless otherwise specified Characteristics Symbol PS21767 Units Tj -20 to 150 °C Storage Temperature Tstg -40 to 125 °C Case Operating Temperature (Note 1) TC -20 to 100 °C Mounting Torque, M3 Mounting Screws — 8.
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 PS21767 Intellimod™ Module Dual-In-Line Intelligent Power Module 30 Amperes/600 Volts Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units — 1.60 2.
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 PS21767 Intellimod™ Module Dual-In-Line Intelligent Power Module 30 Amperes/600 Volts Thermal Characteristics Characteristic Junction to Case* Symbol Condition Min. Typ. Max. Units Rth(j-c)Q Inverter IGBT (Per 1/6 Module) — — 1.1 °C/Watt Rth(j-c)D Inverter FWDi (Per 1/6 Module) — — 2.8 °C/Watt Min. Typ.
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 PS21767 Intellimod™ Module Dual-In-Line Intelligent Power Module 30 Amperes/600 Volts Short Circuit Protection (Lower-arms Only with External Shunt Resistor and RC Filter) A.
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 PS21767 Intellimod™ Module Dual-In-Line Intelligent Power Module 30 Amperes/600 Volts Under-Voltage Protection (Upper-arm, UVDB) C.
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 PS21767 Intellimod™ Module Dual-In-Line Intelligent Power Module 30 Amperes/600 Volts Application Circuit +15V C2 P VUFB VVFS C2 VWFS C1 + C2 +VCC GATE DRIVE UV PROT. VWFB VP1 WP +VCC HVIC C5 INPUT CONDITION C2 R2 W VNO UN VN R2 R2 WN FO CFO C5 C5 C5 C4 CIN VNC C3 VN1 + C2 RSHUNT INPUT SIGNAL CONDITIONING FAULT LOGIC UV PROT. +VCC LVIC N(U) GATE DRIVE R2 OVER CURRENT PROTECTION R3 Typ.
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 PS21767 Intellimod™ Module Dual-In-Line Intelligent Power Module 30 Amperes/600 Volts COLLECTOR-EMITTER SATURATION VOLTAGE CHARACTERISTICS (TYPICAL - INVERTER PART) FREE-WHEEL DIODE FORWARD CHARACTERISTICS (TYPICAL - INVERTER PART) COLLECTOR CURRENT, -IC, (AMPERES) 1.5 1.0 VD = 15V Tj = 25°C Tj = 125°C 0.5 0 10 20 30 40 50 30 20 10 0 0.5 1.0 1.5 2.0 2.
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 PS21767 Intellimod™ Module Dual-In-Line Intelligent Power Module 30 Amperes/600 Volts SWITCHING TIME (ON) VS. COLLECTOR CURRENT (TYPICAL - INVERTER PART N-SIDE) SWITCHING LOSS (OFF) VS.