Thermal Characteristics
Characteristic Symbol Condition Min. Typ. Max. Units
Junction to Case R
th(j-c)Q
Inverter IGBT (Per 1/6 Module) — — 1.3 °C/Watt
R
th(j-c)D
Inverter FWDi (Per 1/6 Module) — — 3.0 °C/Watt
Recommended Conditions for Use
Characteristic Symbol Condition Min. Typ. Value Units
Supply Voltage V
CC
Applied between P-N
U
, N
V
, N
W
0 300 400 Volts
Control Supply Voltage V
D
Applied between V
P1
-V
NC
, V
N1
-V
NC
13.5 15.0 16.5 Volts
V
DB
Applied between V
UFB
-V
UFS
,
13.0 15.0 18.5 Volts
V
VFB
-V
VFS
, V
WFB
-V
WFS
Control Supply Variation
dV
D
, dV
DB
— -1 — 1 V/µs
Arm Shoot-through t
DEAD
For Each Input Signal, 2.0 — — µs
Blocking Time T
C
≤ 100°C
PWM Input Frequency f
PWM
T
C
≤ 100°C, T
j
≤ 125°C — — 20 kHz
Allowable Minimum P
WIN(on)
** —
0.3 — — µs
Input Pulse Width P
WIN(off)
*** Below Rated 200V ≤ V
CC
≤ 350V, 1.4 — — µs
Current 13.5V ≤ V
D
≤ 16.5V,
Between Rated 13.0V ≤ V
DB
≤ 18.5V, 2.5 — — µs
Current and 1.7 -20°C ≤ T
C
≤ 100°C, N-line
Times Rated Current Wiring Inductance < 10nH
V
NC
Voltage Variation V
NC
Between V
NC
-N
U
, N
V
, N
W
, -5.0 — 5.0 Volts
(Including Surge)
Junction Temperature T
j
— -20 — 125 °C
*The allowable RMS current value depends on the actual application conditions.
**The input signal with ON pulse less than P
WIN(on)
may make no response.
***DIP-IPM may make a delayed response (less than about 2µsec) or no response for the input signal with OFF pulse width less than P
WIN(off)
. Refer to About Delayed Response Against
Shorter Input OFF Signal than P
WIN(off
(P-side Only) and Recommended Wiring Around the Shunt Resistor for detals about N-line inductance.
Delayed Response Against Shorter Input OFF Signal than P
WIN(off)
(P-side Only)
t2
t1
P-SIDE
CONTROL INPUT
INTERNAL
IGBT GATE
OUTPUT
CURRENT I
C
Solid Line – OFF Pulse Width > P
WIN(off)
: Turn ON time t1.
Dotted Line – OFF Pulse Width < P
WIN(off)
: Turn ON time t2.