User guide
377
PM75RVA060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
75 Amperes/600 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Control Sector
Over Current Trip Level Brake Part OC -20°C ≤ Tj ≤ 125°C, V
D
= 15V 39 — — Amperes
Short Circuit Trip Level Inverter Part SC -20°C ≤ T
j
≤ 125°C, V
D
= 15V 115 — — Amperes
Short Circuit Trip Level Brake Part — 94 — Amperes
Short Circuit Current Shut-off Time t
off(SC)
V
D
= 15V — 10 — µS
Over Temperature Protection OT Trip Level 100 110 120 °C
(V
D
= 15V, Lower Arm) OT
r
Reset Level 85 95 105 °C
Supply Circuit Under Voltage Protection UV Trip Level 11.5 12.0 12.5 Volts
(-20°C ≤ T
j
≤ 125°C) UV
r
Reset Level — 12.5 — Volts
Circuit Current I
D
V
D
= 15V, V
CIN
= 15V, V
N1
-V
NC
—4460mA
V
D
= 15V, V
CIN
= 15V, V
XP1
-V
XPC
—1318mA
Input ON Threshold Voltage V
CIN(on)
Applied between U
P
-V
UPC
, V
P
-V
VPC
, 1.2 1.5 1.8 Volts
Input OFF Threshold Voltage V
CIN (off)
W
P
-V
WPC
, U
N
, V
N
, W
N
, Br-V
NC
1.7 2.0 2.3 Volts
Fault Output Current I
FO(H)
V
D
= 15V, V
FO
= 15V* — — 0.01 mA
I
FO(L)
V
D
= 15V, V
FO
= 15V* — 10 15 mA
Minimum Fault Output Pulse Width t
FO
V
D
= 15V* 1.0 1.8 — mS
* Fault output is given only when the internal SC, OT, and UV protections circuits of either an upper-arm or a lower-arm device operate to protect it.