User Manual

PM300RLA060
Intellimod™ L-Series
Three Phase IGBT Inverter + Brake
300 Amperes/600 Volts
2
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Absolute Maximum Ratings, T
j
= 25°C unless otherwise specified
Characteristics Symbol PM300RLA060 Units
Power Device Junction Temperature T
j
-20 to 150 °C
Storage Temperature T
stg
-40 to 125 °C
Mounting Torque, M5 Mounting Screws 31 in-lb
Mounting Torque, M5 Main Terminal Screws 31 in-lb
Module Weight (Typical) 800 Grams
Supply Voltage, Surge (Applied between P - N) V
CC(surge)
550 Volts
Self-protection Supply Voltage Limit (Short Circuit protection Capability)* V
CC(prot.)
400 Volts
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal V
ISO
2500 Volts
*V
D
= 13.5 ~ 16.5V, Inverter Part, T
j
= 125°C
IGBT Inverter Sector
Collector-Emitter Voltage (V
D
= 15V, V
CIN
= 15V) V
CES
600 Volts
Collector Current (T
C
= 25°C) ±I
C
300 Amperes
Peak Collector Current (T
C
= 25°C) ±I
CP
600 Amperes
Collector Dissipation (T
C
= 25°C) P
C
801 Watts
IGBT Brake Sector
Collector-Emitter Voltage (V
D
= 15V, V
CIN
= 15V) V
CES
600 Volts
Collector Current (T
C
= 25°C) ±I
C
150 Amperes
Peak Collector Current (T
C
= 25°C) ±I
CP
300 Amperes
Collector Dissipation, T
C
= 25°C (Note 1) P
C
457 Watts
Diode Rated DC Reverse Voltage (T
C
= 25°C) V
R(DC)
600 Volts
Diode Forward Current I
F
150 Amperes
Control Sector
Supply Voltage (Applied between V
UP1
-V
UPC
, V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
) V
D
20 Volts
Input Voltage (Applied between U
P
-V
UPC
, V
P
-V
VPC
, W
P
-V
WPC
, U
N
- V
N
- W
N
-Br-V
NC
) V
CIN
20 Volts
Fault Output Supply Voltage V
FO
20 Volts
(Applied between U
FO
-V
UPC
, V
FO
-V
VPC
, W
FO
-V
WPC
, F
O
-V
NC
)
Fault Output Current (U
FO
, V
FO
, W
FO
, F
O
Terminals) I
FO