User Manual

PM300CLA120
Intellimod™ L-Series
Three Phase IGBT Inverter
300 Amperes/1200 Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
3Rev. 12/05
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
IGBT Inverter Sector
Collector-Emitter Cutoff Current I
CES
V
CE
= V
CES
, V
CIN
= 15V, T
j
= 25°C 1.0 mA
V
CE
= V
CES
, V
CIN
= 15V, T
j
= 125°C 10 mA
Diode Forward Voltage V
EC
-I
C
= 300A, V
CIN
= 15V, V
D
= 15V 2.8 3.9 Volts
Collector-Emitter Saturation Voltage V
CE(sat)
V
D
= 15V, V
CIN
= 0V, I
C
= 300A, 1.8 2.3 Volts
T
j
= 25°C
V
D
= 15V, V
CIN
= 0V, I
C
= 300A, 1.9 2.4 Volts
T
j
= 125°C
Inductive Load Switching Times t
on
0.5 1.0 2.5 µs
t
rr
V
D
= 15V, V
CIN
= 0 1 15V 0.5 0.8 µs
t
C(on)
V
CC
= 600V, I
C
= 300A 0.4 1.0 µs
t
off
T
j
= 125°C 2.3 3.5 µs
t
C(off)
0.7 1.2 µs
Control Sector
Short Circuit Trip Level SC -20°C T
j
125°C, V
D
= 15V 600 Amperes
Short Circuit Current Delay Time t
off(SC)
V
D
= 15V 0.2 µs
Over Temperature Protection OT Trip Level 135 145 °C
(Detect T
j
of IGBT Chip) OT
R
Reset Level 125 °C
Supply Circuit Under-voltage Protection UV Trip Level 11.5 12.0 12.5 Volts
(-20 T
j
125°C) UV
R
Reset Level 12.5 Volts
Circuit Current I
D
Upper Arm V
D
= 15V, V
CIN
= 15V 20 27 mA
Lower Arm V
D
= 15V, V
CIN
= 15V 20 27 mA
Input ON Threshold Voltage V
th(on)
Applied between U
P
-V
UPC
, V
P
-V
VPC
, 1.2 1.5 1.8 Volts
Input OFF Threshold Voltage V
th(off)
W
P
-V
WPC
, U
N
-V
UNC
, V
N
-V
VNC
, W
N
-V
WNC
1.7 2.0 2.3 Volts
Fault Output Current* I
FO(H)
V
D
= 15V, V
FO
= 15V 0.01 mA
I
FO(L)
V
D
= 15V, V
FO
= 15V 10 15 mA
Fault Output Pulse Width* t
FO
V
D
= 15V 1.0 1.8 ms
*Fault output is given only when the internal SC, OT and UV protection of either upper or lower arms is tripped.