User Manual

PM300CLA120
Intellimod™ L-Series
Three Phase IGBT Inverter
300 Amperes/1200 Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
2 Rev. 12/05
Absolute Maximum Ratings, T
j
= 25°C unless otherwise specified
Characteristics Symbol PM300CLA120 Units
Power Device Junction Temperature T
j
-20 to 150 °C
Storage Temperature T
stg
-40 to 125 °C
MMounting Torque, M5 Mounting Screws 31 in-lb
Mounting Torque, M6 Main Terminal Screws 40 in-lb
Module Weight (Typical) 1250 Grams
Supply Voltage, Surge (Applied between P - N) V
CC(surge)
1000 Volts
Self-protection Supply Voltage Limit (Short Circuit protection Capability)* V
CC(prot.)
800 Volts
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal V
ISO
2500 Volts
*V
D
= 13.5 ~ 16.5V, Inverter Part, Tj = 125°C
IGBT Inverter Sector
Collector-Emitter Voltage (V
D
= 15V, V
CIN
= 15V) V
CES
1200 Volts
Collector Current (T
C
= 25°C) ±I
C
300 Amperes
Peak Collector Current (T
C
= 25°C) ±I
CP
600 Amperes
Collector Dissipation (T
C
= 25°C) P
C
1562 Watts
Control Sector
Supply Voltage (Applied between V
UP1
-V
UPC
, V
VP1
-V
VPC
, V
D
20 Volts
V
WP1
-V
WPC
, V
UN1
-V
UNC
, V
WN1
-V
WNC
, V
N1
-V
NC
)
Input Voltage (Applied between U
P
-V
UPC
, V
P
-V
VPC
, W
P
-V
WPC
, V
CIN
20 Volts
U
N
-V
UNC
, V
N
-V
VNC
, W
N
-V
WNC
)
Fault Output Supply Voltage (Applied between U
PFO
-V
UPC
, V
PFO
-V
VPC
, V
FO
20 Volts
W
PFO
-V
WPC
, U
NFO
-V
UNC
, V
NFO
-V
VNC
, W
NFO
-V
WNC
)
Fault Output Sink Current at U
PFO
, V
PFO
, W
PFO
, U
NFO
, V
NFO
, W
NFO
Terminals I