Owner manual
PM25RLB120
Intellimod™ L-Series
Three Phase IGBT Inverter + Brake
25 Amperes/1200 Volts
2
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Absolute Maximum Ratings, T
j
= 25°C unless otherwise specified
Characteristics Symbol PM25RLB120 Units
Power Device Junction Temperature T
j
-20 to 150 °C
Storage Temperature T
stg
-40 to 125 °C
Mounting Torque, M5 Mounting Screws — 31 in-lb
Module Weight (Typical) — 340 Grams
Supply Voltage, Surge (Applied between P - N) V
CC(surge)
1000 Volts
Self-protection Supply Voltage Limit (Short Circuit protection Capability)* V
CC(prot.)
800 Volts
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal V
ISO
2500 Volts
*VD = 13.5 ~ 16.5V, Inverter Part, Tj = 125°C
IGBT Inverter Sector
Collector-Emitter Voltage (V
D
= 15V, V
CIN
= 15V) V
CES
1200 Volts
Collector Current (T
C
= 25°C) ±I
C
25 Amperes
Peak Collector Current (T
C
= 25°C) ±I
CP
50 Amperes
Collector Dissipation (T
C
= 25°C) P
C
116 Watts
IGBT Brake Sector
Collector-Emitter Voltage (V
D
= 15V, V
CIN
= 15V) V
CES
1200 Volts
Collector Current (T
C
= 25°C) ±I
C
15 Amperes
Peak Collector Current (T
C
= 25°C) ±I
CP
30 Amperes
Collector Dissipation (T
C
= 25°C) P
C
100 Watts
Diode Rated DC Reverse Voltage (T
C
= 25°C) V
R(DC)
1200 Volts
Diode Forward Current I
F
15 Amperes
Control Sector
Supply Voltage (Applied between V
UP1
-V
UPC
, V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
) V
D
20 Volts
Input Voltage (Applied between U
P
-V
UPC
, V
P
-V
VPC
, W
P
-V
WPC
, U
N
- V
N
- W
N
-Br-V
NC
) V
CIN
20 Volts
Fault Output Supply Voltage V
FO
20 Volts
(Applied between U
FO
-V
UPC
, V
FO
-V
VPC
, W
FO
-V
WPC
, F
O
-V
NC
)
Fault Output Current (U
FO
, V
FO
, W
FO
, F
O
Terminals) I
FO
20 mA
Arm UP VP WP UN VN WN Br
Axis IGBT FWDi IGBT FWDi IGBT FWDi IGBT FWDi IGBT FWDi IGBT FWDi IGBT FWDi
X 29.0 29.3 64.0 65.5 85.6 85.9 37.8 37.5 55.2 55.7 75.8 75.3 19.0 22.3
Y -7.1 1.5 -7.1 2.0 -7.1 2.0 5.1 -4.5 5.1 -4.5 5.1 -4.5 -7.3 6.6
T
C
(Base Plate) Measurement Point
Y
X
BOTTOM VIEW