Owner manual

PM200RSD060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
200 Amperes/600 Volts
4
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
haracteristics Symbol Test Conditions Min. Typ. Max. Units
Control Sector
Over Current Trip Level Inverter Part OC T
j
= -20°C—690 Amperes
(V
D
= 15V) T
j
= 25°C 351 413 570 Amperes
T
j
= 125°C 310 Amperes
Over Current Trip Level Brake Part OC -20°C T
j
125°C, V
D
= 15V 115 161 Amperes
Short Circuit Trip Level Inverter Part SC -20°C T
j
125°C, V
D
= 15V 560 Amperes
Short Circuit Trip Level Brake Part 241 Amperes
Over Current Delay Time t
off(OC)
V
D
= 15V 10 µS
Over Temperature Protection (V
D
= 15V) OT Trip Level 111 118 125 °C
OT
R
Reset Level 100 °C
Supply Circuit Under Voltage Protection UV Trip Level 11.5 12.0 12.5 Volts
(-20 T
j
125°C) UV
R
Reset Level 12.5 Volts
Circuit Current I
D
V
D
= 15V, V
CIN
= 15V, V
N1
-V
NC
—6082mA
V
D
= 15V, V
CIN
= 15V, V
XP1
-V
XPC
—1520mA
Thermal Voltage ON V
th(on)
Applied between 1.2 1.5 1.8 Volts
Thermal Voltage OFF V
th (off)
U
P
, V
P
, W
P
, U
N
, V
N
, W
N,
B
r
-V
NC
1.7 2.0 2.3 Volts
Input ON Threshold Voltage V
CIN(on)
Applied between 0.8 Volts
Input OFF Threshold Voltage V
CIN(off)
U
P
, V
P
, W
P
, U
N
, V
N
, W
N,
B
r
-V
NC
4.0 Volts
Fault Output Current* I
FO(H)
V
D
= 15V, V
FO
= 15V 0.01 mA
I
FO(L)
V
D
= 15V, V
FO
= 15V 10 15 mA
Minimum Fault Output Pulse Width* t
FO
V
D
= 15V 1.0 1.8 mS
*Fault output is given only when the internal OC, SC, OT and UV protections schemes of either upper or lower devide operate to protect it.