Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Thermal Characteristics
Characteristic Symbol Condition Min. Typ. Max. Units
Junction to Case Thermal Resistance R
th(j-c)Q
IGBT (Per 1/6 Module) (Note 1) — — 0.21 °C/Watt
R
th(j-c)D
FWDi (Per 1/6 Module) (Note 1) — — 0.33 °C/Watt
R
th(j-c)Q
IGBT (Per 1/6 Module) — — 0.16 °C/Watt
R
th(j-c)D
FWDi (Per 1/6 Module) — — 0.25 °C/Watt
Contact Thermal Resistance R
th(c-f)
Case to Fin Per Module, — — 0.023 °C/Watt
Thermal Grease Applied
Recommended Conditions for Use
Characteristic Symbol Condition Value Units
Supply Voltage V
CC
Applied across P-N Terminals ≤400 Volts
Control Supply Voltage* V
D
Applied between V
UP1
-V
UPC
, 15.0 ± 1.5 Volts
V
VP1
-V
VPC
, V
WP1
-V
WPC
,
V
N1
-V
NC
Input ON Voltage V
CIN(on)
Applied between U
P
-V
UPC
, ≤0.8 Volts
Input OFF Voltage V
CIN(off)
V
P
-V
VPC
, W
P
-V
WPC
, U
N
- V
N
- W
N
-V
NC
≥9.0 Volts
PWM Input Frequency f
PWM
— ≤20 kHz
Arm Shoot-through Blocking Time t
DEAD
Input Signal ≥2.0 µs
*With ripple satisfying the following conditions: dv/dt swing ≤ ±5V/µs, Variation ≤ 2V peak to peak.