User guide

3
PM1200HCE330-1
High Voltage Intelligent Power Module
1200 Amperes/3300 Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
ElectricalCharacteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Control Part
Supply Voltage V
D
Applied between V
1
~ V
C
21.6 24.0 26.4 Volts
Circuit Current I
D
V
D
= 24V, T
j
= 25°C—80120 mA
Input ON Threshold Voltage V
th(on)
Applied between C
1
~ V
C
6.1 6.7 7.3 Volts
Input OFF Threshold Voltage V
th(off)
10.5 11.1 11.7 Volts
Minimum Fault Output Pulse Width t
FO
V
D
= 24V 100 200 µs
Overcurrent Trip Level OC T
j
= -25°C ~ 125°C 2200 Amperes
Overtemperature Protection OT Trip Level 103 113 123 °C
(Baseplate Temperature Detection) OT
r
Reset Level 88 98 108 °C
Supply Circuit Undervoltage Protection UV Trip Level 19.2 20.0 20.8 Volts
(T
j
= -25°C ~ 125°C) UV
r
Reset Level 20.5 Volts
Inverter Part
Collector-Emitter Saturation Voltage V
CE(sat)
I
C
= 1200A, T
j
= 25°C—3.05 3.97 Volts
FWDi Forward Voltage V
EC
-I
C
= 1200A, T
j
= 25°C—2.90 3.77 Volts
Collector Cutoff Current I
CES
V
CE
= V
CES
, T
j
= 25°C—15mA
V
CE
= V
CES
, T
j
= 125°C—60mA