Owner manual
3
PM100RSD060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
100 Amperes/600 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
IGBT Inverter Sector
Collector Cutoff Current I
CES
V
CE
= V
CES
, T
j
= 25°C, ——1.0 mA
V
D
= 15V
V
CE
= V
CES
, T
j
= 125°C, ——10 mA
V
D
= 15V
Diode Forward Voltage V
EC
-I
C
= 100A, V
D
= 15V, V
CIN
= 15V — 2.2 3.3 Volts
Collector-Emitter Saturation Voltage V
CE(sat)
V
D
= 15V, V
CIN
= 0V, I
C
= 100A, — 1.7 2.3 Volts
T
j
= 25°C
V
D
= 15V, V
CIN
= 0V, I
C
= 100A, — 1.7 2.3 Volts
T
j
= 125°C
Inductive Load Switching Times t
on
0.8 1.2 2.4 µS
t
rr
V
D
= 15V, V
CIN
= 0 ~ 15V — 0.15 0.3 µS
t
C(on)
V
CC
= 300V, I
C
= 100A — 0.4 1.0 µS
t
off
T
j
= 125°C — 2.4 3.3 µS
t
C(off)
— 0.6 1.2 µS
IGBT Brake Sector
Collector Cutoff Current I
CES
V
CE
= V
CES
, T
j
= 25°C, ——1.0 mA
V
D
= 15V
V
CE
= V
CES
, T
j
= 125°C, ——10 mA
V
D
= 15V
FWDi Forward Voltage V
FM
-I
F
= 30A — 2.5 3.5 Volts
Collector-Emitter Saturation Voltage V
CE(sat)
V
D
= 15V, V
CIN
= 0V, I
C
= 30A, — 1.8 2.5 Volts
T
j
= 25°C
V
D
= 15V, V
CIN
= 0V, I
C
= 30A, — 1.9 2.6 Volts
T
j
= 125°C