Owner manual

D-35
Powerex, Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (724) 925-7272
CN24_ _10, CD24_ _10
Fast Recovery Dual Diode Modules
100 Amperes/600-1200 Volts
Electrical and Thermal Characteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions CN24_ _10/CD24_ _10 Units
Blocking State Maximums
Reverse Leakage Current, Peak I
RRM
T
j
= 150°C, V
RRM
= Rated 20 mA
Conducting State Maximums
Peak On-State Voltage V
FM
I
FM
= 100A 1.5 Volts
Switching Maximums
Reverse Recovery Time t
rr
I
FM
= 100A, T
j
= 150°C 0.8 ms
di/dt =-200A/ms, V
R
= 1/2V
RM
Reverse Recovery Charge Q
rr
I
FM
= 100A, T
j
= 150°C 30 mC
di/dt =-200A/ms, V
R
= 1/2V
RM
Thermal Maximums
Thermal Resistance, Junction-to-Case R
u(J-C)
Per Module 0.5 °C/Watt
Thermal Resistance, Case-to-Sink (Lubricated) R
u(C-S)
Per Module 0.4 °C/Watt