Fig. 1 - Current Rating Characteristics
Fig. 2 - Current Rating Characteristics
Fig. 4 - Forward Power Loss Characteristics
Fig. 3 - Forward Power Loss Characteristics
Fig. 6 - Maximum Non-Repetitive Surge Current
Fig. 5 - Forward Voltage Drop Characteristics
Instantaneous Forward Voltage (V)
Instantaneous Forward Current (A)
Maximum Allowable Case Temperature (°C)
Average Forward Curren t (A)
95
100
105
110
115
120
125
130
135
140
145
150
0 5 10 15 20 25 30 35 40 45
30˚
60˚
90˚
120˚
180˚
Conduction Angle
40EPS16
RthJC (DC) = 0.6 K/W
Maximum Allowable Case Temperature (°C)
Average Forward Curren t (A)
Maximum Average Forward Power Loss (W)
Average Forward Curren t (A)
Maximum Average Forward Power Loss (W)
Average Forward Curren t (A)
Pulse Train Duration (s)
Peak Half Sine Wave Forward Current (A)
100
110
120
130
140
150
0 10203040506070
DC
30˚
60˚
90˚
120˚
180˚
Conduction Period
40EPS16
RthJC (DC) = 0.6 K/W
0
5
10
15
20
25
30
35
40
45
50
55
60
0 5 10 15 20 25 30 35 40
RMS Limit
Conduction Angle
180˚
120˚
90˚
60˚
30˚
40EPS16
Tj = 150˚C
0
10
20
30
40
50
60
70
80
0 10203040506070
DC
180˚
120˚
90˚
60˚
30˚
RMS Limit
Conduction Period
40EPS16
Tj = 150˚C
1
10
100
1000
0.5 1.5 2.5
Tj = 25˚C
Tj = 150˚C
40EPS16
100
150
200
250
300
350
400
450
500
0.01 0.1 1
Maximum Non Repetitive Surge Current
40EPS16
Initial Tj = 150 ˚C
No Voltage Reapplied
Rated Vrrm Reapplied
Versus Pulse Train Duration.
Document Number: 93512
www.vishay.com
3