Instruction Manual

Document Number: 94355 For technical questions, contact: ind-modules@vishay.com
www.vishay.com
Revision: 29-Apr-08 3
200MT40KPbF
Three Phase Bridge
(Power Module), 200 A
Vishay High Power Products
Fig. 1 - Current Rating Characteristics
Fig. 2 - On-State Voltage Drop Characteristics
Fig. 3 - Maximum Non-Repetitve Surge Current
Fig. 4 - Maximum Non-Repetitive Surge Current
Fig. 5 - Current Rating Nomogram (1 Module Per Heatsink)
70
120
130
140
110
100
90
80
Maximum Allowable Case
Temperature (°C)
Total Output Current (A)
80 100 120 140 160 180 200 22060
120°
(Rect)
1
100
10
1000
Peak Half Sine Wave
On-State Current
Number of Equal Amplitude
Half Cycle Current Pulses (N)
1.0 1.5 2.0 2.5
3.0
0.5
T
J
= 150 °C
T
J
= 25 °C
800
600
400
1400
1600
1200
1000
Instantaneous On-State Current (A)
Instantaneous On-State Voltage (V)
10 1001
Per junction
At any rated load condition and with
rated V
RRM
applied following surge.
Initial T
J
= 150 ˚C
at 60 Hz 0.0083 s
at 50 Hz 0.0100 s
0
200
400
600
800
2000
1800
1600
1400
1200
1000
Peak Half Sine Wave
On-State Current (A)
Pulse Train Duration (s)
0.1
1.0
10
0.01
Maximum non-repetitive surge current
versus pulse train duration. Control
Per junction
of conduction may not be maintained.
Initial T
J
= 150 ˚C
No voltage reapplied
Rated V
RRM
reapplied
0
100
200
300
400
500
Maximum Total Power Loss (W)
Total Output Current (A)
40 80 120 160
200
0
120°
(Rect)
T
J
= 125 °C
0
100
200
300
400
500
Maximum Total Power Loss (W)
Maximum Allowable Ambient
Temperature (°C)
306090120
150
0
R
thSA
= 0.025 K/W - ΔR
0.05 K/W
0.1 K/W
0.2 K/W
0.3 K/W
0.5 K/W
1.0 K/W