User Manual
www.vishay.com For technical questions, contact: ind-modules@vishay.com
Document Number: 94353
8 Revision: 29-Apr-08
53-93-113MT..KPbF Series
Vishay High Power Products
Three Phase Controlled Bridge
(Power Modules), 55 A to 110 A
ORDERING INFORMATION TABLE
Note
• To order the optional hardware go to www.vishay.com/doc?95172
CIRCUIT CONFIGURATION
Device code
1 - Current rating code: 5 = 55 A (average)
2 - Circuit configuration code: 3 = Full-controlled bridge
3 - Essential part number
4 - Voltage code x 10 = V
RRM
(see Voltage Ratings table)
5 - Critical dV/dt:
6 -
PbF = Lead (Pb)-free
9 = 90 A (average)
11 = 110 A (average)
2 = Postive half-controlled bridge
1 = Negative half-controlled bridge
S90 = 1000 V/µs (special selection)
None = 500 V/µs (standard value)
5132 6
11 3 MT 160 K S90 PbF
4
negative half-controlled bridge
(51, 91, 111MT..K)
positive half-controlled bridge
(52, 92, 112MT..K)
full-controlled bridge
(53, 93, 113MT..K)
A
D
1
B
EF
C
25
64 3
AB C
D
EF
125
A
DE F
BC
LINKS TO RELATED DOCUMENTS
Dimensions http://www.vishay.com/doc?95004