U S E R ’ S M A N U A L 16-CHANNEL FORM A SWITCH M-MODULE MODEL M218 (FORMERLY HP E2270A) Document Part No: 11029534 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas 78681 <> www.chtech.
COPYRIGHT C&H Technologies, Inc. (C&H) provides this manual "as is" without warranty of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. C&H may make improvements and/or changes in the product(s) and/or program(s) described in this manual at any time and without notice. This publication could contain technical inaccuracies or typographical errors.
AMENDMENT NOTICE C&H Technologies, Inc. makes every attempt to provide up-to-date manuals with the associated equipment. Occasionally, changes are made to the equipment wherein it is necessary to provide amendments to the manual. If any amendments are provided for this manual they are printed on colored paper and will be provided with the module and manual. Manual updates may also be found on out web site at www.chtech.com.
INTRODUCTION This manual describes the operation and use of the C&H Model M218 16-Channel Form A Switch M-Module (Part Number 11029530). This module was formerly manufactured by HP (Agilent) as Model E2270A. C&H obtained the manufacturing rights from Agilent and now manufacturers it as C&H Model M218. This mezzanine module is designed to interface within any M/MA-Module carrier adhering to the ANSI/VITA 12-1996 M-Module specification.
TABLE OF CONTENTS 1.0 GENERAL DESCRIPTION................................................................................................ 1 1.1 PURPOSE OF EQUIPMENT ................................................................................... 1 1.2 SPECIFICATIONS OF EQUIPMENT...................................................................... 1 1.2.1 Key Features ............................................................................................ 1 1.2.2 Specifications ......................
LIST OF FIGURES Figure 1. Figure 2. Figure 3. Figure 4. M-MODULE Installation ............................................................................................ 5 M218 Functional Block Diagram................................................................................. 7 M218 Switching Schematic ......................................................................................... 9 M218 I/O Registers..........................................................................................
1.0 GENERAL DESCRIPTION The M218 provides 16 one-wire switches on a single wide M-Module adhering to the ANSI/VITA 12-1996 specification for M-Modules. The M218 may be installed on any carrier board supporting the M-Module specification. Carriers are available that allow the M218 to be used in Ethernet, VXI, VME, PCI, cPCI and other system architectures. 1.
1.2.2 Specifications The M218 incorporates the standard 40-pin, 20x2 row connector interfaces to the carrier board for power and data/control, but does not have the 24-pin optional connector for carrying userconnections back onto the carrier board. The user input/output is provided through a standard 44-pin D-subminiature female receptacle. A mating connector kit can be ordered separately as AM111 (C&H Part Number 11029700-0001). CONEC part number 302A10889X (or equivalent) is used on the assembly.
1.2.3 Mechanical The mechanical dimensions of the module are in conformance with ANSI/VITA 12-1996 for single-wide M-Module modules. The nominal dimensions are 5.687” (144.5 mm) long 2.082” (52.9 mm) wide. 1.2.4 Bus Compliance The module complies with the ANSI/VITA 12-1996 Specification for single-wide M-Modules and the MA-Module trigger signal extension. The module also supports the optional IDENT and VXI-IDENT functions.
4 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas 78681 <> www.chtech.
2.0 INSTALLATION 2.1 UNPACKING AND INSPECTION Verify that there has been no damage to the shipping container. If damage exists then the container should be retained, as it will provide evidence of carrier caused problems. Such problems should be reported to the shipping courier immediately, as well as to C&H. If there is no damage to the shipping container, carefully remove the module from its box and anti static bag and inspect for any signs of physical damage. If damage exists, report immediately to C&H.
2.4 PREPARATION FOR RESHIPMENT If the module is to be shipped separately it should be enclosed in a suitable water and vapor proof anti-static bag. Heat seal or tape the bag to insure a moisture-proof closure. When sealing the bag, keep trapped air volume to a minimum. The shipping container should be a rigid box of sufficient size and strength to protect the equipment from damage.
3.0 FUNCTIONAL DESCRIPTION 3.1 OVERVIEW A simplified functional block diagram is shown in Figure 2. VCC Carrier Interface DGND A(7:1) ROW _SET(4:1) D(15:0) ROW _RESET(4:1) /CS /IACK VCC /WRITE /DS0 /DS1 Module Control SYSCLK /DTACK Driver Power Switch DR_EN /IRQ +5VDR /RST ROM COL(4:1) ID EEPROM +12V /DACK /DREQ N.C. Column Drivers N.C. N.C. COL_DR(4:1) +5V GND /RESET Row Drivers ROW_DR(4:1) VCC Reset & Power Supply Conditioning DGND ZGND /RST Relay Coils Figure 2.
3.1.3 ID EEPROM The EEPROM holds sixty-four 16-bit words of M-Module ID data and VXI M-Module data. Refer to “ID EEPROM Register” on page 10 for EEPROM contents. 3.1.4 Row and Column Drivers The module uses a matrix drive scheme (rows and columns) in which a maximum of four of the relays (one row) can be operated at any one time. An on-board timer (part of Module Control block) ensures the relay coils have been driven long enough for the contacts to move and settle.
User Connector Pins User Connector Pins Channel 0 Channel 8 1 16 CH0_NO CH0_COM 2 17 CH1_NO CH1_COM 3 18 CH2_NO CH2_COM 4 19 CH3_NO CH3_COM 5 20 CH4_NO CH4_COM 6 21 CH5_NO CH5_COM 7 22 CH6_NO CH6_COM 8 23 CH7_NO CH7_COM Channel 1 9 24 CH8_NO CH8_COM 10 25 CH9_NO CH9_COM 11 26 CH10_NO CH10_COM 12 27 CH11_NO CH11_COM 13 28 CH12_NO CH12_COM 14 29 CH13_NO CH13_COM 15 30 CH14_NO CH14_COM 43 44 CH15_NO CH15_COM Channel 9 Channel 2 Channel 10 Channel 11 Channel 3 Channel 4
3.2 IDENTIFICATION AND CONFIGURATION REGISTERS 3.2.1 I/O Registers There are a variety of registers used to configure and control the module. These registers are located in the IOSpace. The address map of the registers is shown in Table II. Details of the registers are provided in Figure 4. Table II.
Reg.
Reg. 10 Bit Write Read Row 0 Set Register 15 14 13 12 11 10 9 Unused Unused 15 14 13 12 11 10 9 Unused Unused 15 14 13 12 11 10 9 Unused Unused 15 14 13 12 11 10 9 Unused Unused 15 14 13 12 11 10 9 Unused Unused 15 14 13 12 11 10 9 Unused Unused 15 14 13 12 11 10 9 Unused Unused 15 14 13 12 11 10 9 Unused Unused Reg.
3.2.2 Module Identification The M218 supports the identification function called IDENT. This IDENT function provides information about the module and is stored in a sixteen-word deep (32 byte) serial PROM. Access is accomplished with read/write operations on the last address in IOSpace (hex FE) and the data is read one bit at a time. The PROM is compatible with a standard IC 9603 type PROM. For specific timing information refer to the 9603 or compatible PROM data sheet.
4.0 OPERATION The M218 is a register-based instrument that is controlled through a series of I/O registers described in Section 3.2.1. The exact method of accessing and addressing the I/O registers is dependent on the M-Module carrier used to interface the module to your data acquisition or test system. Refer to the carrier’s documentation for information on the address mapping of an MModule’s I/O registers and to your system software documentation for details on data access.
3. The Row n Set/Reset readback registers return the programmed relay state only if you use the module correctly. Since the driver power can be disabled (the power-on state), the Row n Set and Row n Reset registers can be written to and read from without moving any relay contacts. 4. When the module loses power, any closed relays remain closed (latching relays). When power is restored, the relays remain closed but the Row n Set and Row n Reset registers have lost their relay state information.
If the M-Module is enabled to interrupt, it asserts the INT line on the M-Module interface to the Carrier when the last commanded relay operation in the FIFO has completed. For example, if relays in only one row were instructed to move, the module asserts an interrupt after that one row has been driven. If four rows were instructed to move (four writes to the FIFO--see note below), then the module asserts an interrupt only after the completion of the fourth operation.
APPENDIX A: CONNECTORS MAXIMUM VOLTAGE/CURRENT. The maximum voltage that may be applied to any connector on the M218, M219, or M220 is 200 VDC, 125 VAC rms, or 175 VAC peak--these limits apply only if the product is installed in a humiditycontrolled (<60% RH) environment where airborne contaminants and transients are controlled, and there is NOT a relay connection made to power mains. If these conditions CANNOT be maintained, then the maximum voltage is 60 VDC, 48 VAC-rms or 68 VAC-peak.
A-2 C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas 78681 <> www.chtech.
N O T E S: C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas 78681 <> www.chtech.
. C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas 78681 <> www.chtech.
READER'S COMMENT FORM Your comments assist us in improving the usefulness of C&H's publications; they are an important part of the inputs used for revision. C&H Technologies, Inc. may use and distribute any of the information that you supply in any way that it believes to be appropriate without incurring any obligation whatsoever. You may, of course, continue to use the information, which you supply.
INSTRUCTIONS In its continuing effort to improve documentation, C&H Technologies, Inc. provides this form for use in submitting any comments or suggestions that the user may have. This form may be detached, folded along the lines indicated, taped along the loose edge (DO NOT STAPLE), and mailed. Please try to be as specific as possible and reference applicable sections of the manual or drawings if appropriate.