Instructions
73 C-Control Pro IDE
© 2013 Conrad Electronic
The following reference voltage sources are available:
0,6 * VDDANA internal (0,6 * 3.3V = 1,98V)
internal reference voltage of 1V
two external reference voltage inputs, e.g. 2.048V generated by reference-voltage-IC
If "x" is a digital measurement value, calculate the corresponding voltage value "u" as follows:
The resolution depends on the configuration of the ADC.
Resolution
Maximal Value
8 Bit
-128 to +127
10 Bit
-512 to +511
12 Bit
-2048 to +2047
Formula for calculating the present ADC voltage:
u = x * reference voltage / resolution
CAN Terminating Resistor
Jumper (J2) enables the CAN bus 120 ohm termination resistorus. For more information on CAN-
BUS and its properties, see the chapter CAN bus!
LAN
On pins VCC2 (+3.3 V), GND, RD, RD +, RD, TD +, LED_L and LEDA the connections for the LAN
port are lead through. On the Applicationboard or Mainboard a LAN socket is already present, which
is hardwired to the connectors of the UNIT. In their own applications, where the UNIT is used "stand
alone", the user can retrofit an Ethernet jack himself like shown in the below diagram.