Instructions

26Hardware
© 2013 Conrad Electronic
Timer_3 with 16 bits each. They can be used for D/A conversion, to control servo motors in pattern
making and to output audio frequencies. A pulse length modulated signal has a period of N so called
"Ticks". The duration of one tick is the time base. If the output value of a PLM port is set to X then
the port will hold high level for X ticks of one period and will then for the balance of the period drop to
low level. For programming of the PLM channels see Timer.
The PLM channels for Timer_0, Timer_1 and Timer_3 have independent time base and period length.
In applications for pulse width modulated digital to analog conversion the time base and period length
are set once and then only the output value is varied. According to their electrical properties the PLM
ports are digital ports. Please observe the technical boundary conditions for digital ports (max. cur-
rent).
Technical Data Module
Note: Detailed information can be found in the IC manufacturers PDF files on the C-Control Pro Soft-
ware CD-ROM.
All voltage specifications apply to direct current (DC).
Environmental Conditions
Range of admissible ambient temperature
C … 70°C
Range of admissible relative ambient humidity
20% 60%
Power Supply
Range of admissible operating voltage
4.5V 5.5V
Power consumption of the module without ex-
ternal loads
appr. 20mA
Clock
Clock Frequency (Quartz Oscillator)
14.7456MHz
Mechanics
Overall measurements less pins, appr.
40 mm x 40mm x 8 mm
Weight
appr. 90g
Pin pitch
2.54mm
Number of pins (two rows)
64