Instructions
24Hardware
© 2013 Conrad Electronic
responding socket strips must be organized in the following pitch format:
In the graph the socket strip X1-X4 and then the first two pins of the socket strip can be seen. Pin 1
of strip X1 corresponds to terminal X1_1 (see Mega128 Pinzuordnung).
Module Memory
The C-Control Pro 128 Module provides 128kB FLASH, 4kB EEPROM and 4kB SRAM. A supple-
mentary EEPROM with an 8kB memory depth and an SRAM with a 64kB memory depth is mounted
on the application board. The EEPROM can be addressed by an I2C interface.
Note: Detailed information can be found in the IC manufacturer’s PDF files on the C-Control Pro Soft-
ware CD-ROM.
ADC Reference Voltage Generation
The Micro Controller is equipped with an analog-to-digital converter with a 10 Bit resolution. This
means that measured voltages can be represented by integral numbers from 0 through 1023. The ref-
erence voltage for the lower limit is GND level, i. e. 0V. The reference voltage for the upper limit can
be selected by the user:
5V Operating Voltage (VCC)
Internal Reference Voltage of 2.56V
External Reference Voltage e. g. 4.096V generated by a Reference Voltage IC.
If x is a digital measuring value then the corresponding voltage value u is computed as follows:
u = x * Reference Voltage / 1024