Instructions

148IDE
© 2013 Conrad Electronic
several Debug Functions.
With a right mouse click in the Debug Outputs section the following commands can be selected:
Delete – will delete the list of Debug outputs
Copy to Clipboard – will copy all text messages onto the clipboard
3.3.6 PIN Functions
Some solitary functions of the Interpreter can be protected by use of an alpha-numeric PIN. If an In-
terpreter is protected by a PIN normal operations are prohibited. By means of a new transfer the In-
terpreter can be overwritten, the PIN will however stay preserved. Also a normal start other than the
Autostart behaviour is no longer allowed. Furthermore the scans of hardware and firmware version
numbers are locked.
If access to a forbidden function is tried a dialod with the following text will be displayed: "C-Control
is Password protected. Operation not allowed!".
Through inscription of the PIN with Enter PIN in the C-Control Menu all operations can again be re-
leased.
In order to enter a new PIN or to delete a set PIN there are the commands Set PIN and Delete PIN in
the C-Control Menu. If there is an old PIN in exitence then the Module must of course first be un-
locked by entering the old PIN. The PIN can have a length of up to 6 alpha-numeric characters.
In case the password has been lost there is an emergency function which can be used to reset
the Module to its initial state. In C-Control there is the option Reset Module which can be used to de-
lete PIN, Interpreter and Program.
3.3.7 Version Check
Since the C-Control Pro Mega Series supports various hardware platforms it is important to closely
monitor the current version numbers of Bootloader, Interpreter and Hardware. This is possible by use
of item Hardware Version in the C-Control menu.