Instructions

146IDE
© 2013 Conrad Electronic
You can enter the current network settings, the UDP port of the bootloader and the MAC address.
To avoid connection problems, the MAC address should be set to a new value before switching
on the Ethernet support. To this end, its own MAC address is generated and supplied on a label for
each C-Control Pro AVR32Bit. See Software Installation.
Options
Ethernet Support - Switches on Ethernet support.
Allow Ping - ICMP echo requests are answered.
Lock Options Access - The C-Control configuration cannot be changed. Only Reset Module only al-
lows this again.
Disable Autostart - Autostart is not performed (see Autostart).
Enable DHCP - Gets network information from a DHCP server.
save DHCP settings ??- Changed DHCP data is stored.
Prohibit external Program Stop - A program cannot stopped by software.
2 sec. Autostart Delay - Autostart is delayed by 2 seconds so that USB is powered up.
3.3.4 Search Ethernet
If Ethernet Support is enabled, the C-Control Pro AVR32Bit module is visible on the local Ethernet
LAN. As the search is performed via UDP broadcast, it is limited to the local subnet, since routers
generally do not forward broadcasts. The default UDP port for the Ethernet access is 50234. This
port should not be restricted by a local firewall on the PC.