Instructions
97 C-Control Pro IDE
© 2013 Conrad Electronic
UNIT-BUS Pin Configuration
Reference Voltage
The jumper JP3 connects the external 2.048V reference voltage to the ADCREF0 (P8) pin of the
UNIT.
CAN Bus
At the clamp with the marking "CAN" the CAN bus (CAN0) is led out of the UNIT and can be used
directly. It must be followed by no driver, since it is a driver already available on the UNIT. On the
socket connector J10 the second CAN bus (CAN1) is led out. This does not have a CAN driver and
can be used as a normal input/output.
LAN Port
The LAN port can be directly connected with a switch or router. The LAN connector is permanently
connected to the pins of UNIT (see pin assignment in the manual). With the Ethernet interface of the
C-Control PRO AVR32Bit a web server can easily be implemented (see demo programs). Further-
more, via the Ethernet bootloader (see manual chapter AVR32Bit Firmware bootloader) the UNIT can
be programmed from afar.
LCD Port
At the 6-pin socket header with marking "LCD PORT" the C-Control PRO AVR32Bit LCD1602 board
(Conrad Order No. 192602) can be attached. The Mainboard is connected with the LCD module via a
6-pin ribbon cable with a pin header connector (female). Because depending on the application, the
cable lengths are varying, we offer these components for self-assembly using the following order
numbers:
Ribbon cable RM1.27 0.05mm²: Order No. 607237
Pin header connectors 2x3 RM:2.54mm: Order No. 742063