User manual

C-COM Satellite Systems Inc. Page 99 of 128
iNetVu™ 7000 Controller User Manual
Revision 1.19
7.2.2.9. Azimuth Parameters
The Azimuth menu allows for the configuration of the azimuth axis. Options include the
setting of the pot zero, and the pot factor, as well as the axis limit functionality, the slow
speed setting, and current limits for fast and slow speeds.
Fig. 75:
Maintenance - Azimuth Parameters
Slow Speed
The iNetVu
TM
software basis the default azimuth motor slow speed on the platform size
and type. See appendix 3, table 5 for details. The user may change this value, however
changing such value could result in difficulty with satellite acquisition.
Limit Switches (ST_DIS, LR_DIS)
Allows for enabling and disabling the ST (STOW) and LR (Azimuth Left and Right) limits.
A check mark in the box implies the limit has been DISABLED. By default the boxes are
left unchecked. Please be advised that disabling any of these limits should be done
under the direct supervision of a C-Com Satellite Systems Inc. technical support
representative.
Note: The LR limit is for future development purposes, and is not functional at the time
of publication.
Current Settings
H_P_C (9) and L_P_C (6) represent high platform current (Amps) @ speed 9, and low
platform current @ speed 6 respectively. A software controlled current protection for the
Mobile Platform’s elevation motors. For Motor Speeds that are not listed (Speed 1, 2, 4,
5, 7, 8), the Current Limit for those speeds is calculated using a percentage of the
Current Limit @ speed 6 and 9. See appendix 3, table 5 for the default current limits for
all iNetVu
TM
Mobile Platforms.
• Current Limit 8 – 90% of Current Limit 9
• Current Limit 7 – 80% of Current Limit 9
• Current Limit 5 – 90% of Current Limit 6
• Current Limit 4 – 80% of Current Limit 6