4 - Polarization Offset
By default this polarization-offset value is set to +0°. If there happens to be a requirement for a
polarization offset, the user may manually enter this value in this area.
5 –Speed Setting
S The user may configure the slow speed of the polarization movement. The slow speed is a
basis for the satellite searching procedure. See appendix 3 for details.
6 – Current Settings
A software controlled current protection for the Mobile Platform’s polarization motors. When any of
the Mobile Platform’s motors are moving at the associated speed, the current drawn to move the
motor is monitored and should it exceed the Current Limit, an error message will appear. For Motor
Speeds that are not listed (Speed 1, 2, 4, 5, 7, 8), the Current Limit for those speeds is calculated
using a percentage of the Current Limit above it. See appendix 3 for the default current limits for all
iNetVu
TM
Mobile Platforms.
• Current Limit 8 – 90% of Current Limit 9
• Current Limit 7 – 80% of Current Limit 9
• Current Limit 5 – 90% of Current Limit 6
• Current Limit 4 – 80% of Current Limit 6
• Current Limit 2 – 90% of Current Limit 3
• Current Limit 1 – 80% of Current Limit 3
I Configurable Current Limit For High Speed (9) movement is to the left of the dash, and
Configurable Current Limit For Slow Speed (6) movement is to the right of the dash.
(i.e. I: 1.5-1.2 Represents Current Limit of 1.5 A @ speed 9, and Current Limit of
1.2 A @ speed 7)