User manual

C-COM Satellite Systems Inc. Page 47 of 128
iNetVu™ 7000 Controller User Manual
Revision 1.19
3 - Advanced Search Elevation Gap
With a configurable range of (2º-20º) this parameter is used to determine the small incremental
adjustments required for a more accurate satellite search. Decreasing this value will add accuracy
to the Search Window, but will increase the search time. This value is used while searching on an
inclined surface. For instance A: 03 means the elevation angle will adjust if 3º gap from the
calculated angle. This value is set by default for optimum performance.
4 – Limit Switches (L: EEE)
Allows the enabling and disabling of the UP, DOWN, and STOW limits respectively.
The first character (EEE) represents the UP limit. The second character (EEE) represents the
DOWN limit and the third character (EE
E) represents the STOW limit. The user my change the limit
configuration between:
E – Enable Limit
D – Disable Limit
D - Disable Limit
This option disables UP, DN, and ST limits for testing and troubleshooting (i.e. DEE – represents
disabled Up limit, and enabled down and stow limit).
E – Enable Limit
Once enabled, the up, down and stow limits will be activated whenever the up, down, and stow
sensors have been triggered on the iNetVu
TM
Mobile platform.
5 –Speed Setting
S The user may configure the slow speed of the elevation movement. The slow speed is a
basis for the satellite searching procedure.
6 – Current Settings
A software controlled current protection for the Mobile Platform’s elevation motors. When any of the
Mobile Platform’s motors are moving at the associated speed, the current drawn to move the motor
is monitored and should it exceed the Current Limit, an error message will appear. For Motor
Speeds that are not listed (Speed 1, 2, 4, 5, 7, 8), the Current Limit for those speeds is calculated
using a percentage of the Current Limit above it. See appendix 3 for the default current limits for all
iNetVu
TM
Mobile Platforms.
• Current Limit 8 – 90% of Current Limit 9
• Current Limit 7 – 80% of Current Limit 9
• Current Limit 5 – 90% of Current Limit 6
• Current Limit 4 – 80% of Current Limit 6
• Current Limit 2 – 90% of Current Limit 3
• Current Limit 1 – 80% of Current Limit 3
I Configurable Current Limit For High Speed (9) movement is to the left of the dash, and
Configurable Current Limit For Slow Speed (6) movement is to the right of the dash.
(i.e. I: 12-05 Represents Current Limit of 12 A @ speed 9, and Current Limit of 5 A @ speed 6)