User manual

C-COM Satellite Systems Inc. Page 22 of 128
iNetVu™ 7000 Controller User Manual
Revision 1.19
6.2. Manual and Automatic Controls Button Operation
Fig. 8: iNetVu™ 7000 Controller Front Panel Buttons
How to Find Satellite
Press “FIND SAT” Button.
iNetVu™ Mobile Platform will automatically attempt to locate, lock, peak and enable the system onto the
configured satellite.
How to Stow the Antenna
Press “STOP/STOW” Button, and hold for 2 seconds.
iNetVu™ Mobile Platform will automatically re-center itself and lower into the stow position.
How to Stop
Press “STOP/STOW” Button (do not hold). Stops all ongoing operations such as motor movements and
automatic functions like Find Satellite and Stow.
How to Manually Move the Mobile Platform
Press “SELECT” to select the axis of motion you wish to move. The LED corresponding to the axes chosen
will light up. Press “SPEED H/L” to select the speed (LED ON – HI, LED OFF - LOW). Press and release “+”
and “–“ for short duration movement & angle readings. Press and hold “+” and “–“ for long duration
movement. Warning: User must watch antenna limit sensors (EL UP/ST, AZ ST, PL ST) when using
manual controls. See LCD ‘Monitor’ section explanation for more details.
How to Turn ON/OFF the Controller
Turn off the power switch on the back panel of the iNetVu
TM
7000 Controller.
How to Reset the Controller
Press “RESET” Button
Power-cycles the iNetVu™ Controller
DOES NOT reset default values