iNetVu™ 7000 Controller User Manual
Revision 1.19
PL Pot Zero
PL Pot Zero is an A/D value from the potentiometer that physically determines where the
iNetVu™ Mobile Software places Polarization Angle 0°. The PL Pot Zero may vary
approximately +15% from the Default values (see appendix 3). The PL Pot Zero is
calculated during the Polarization Calibration process. The user may edit these values
through this window, however any changes may result in failure to recognize the correct
0° angle.
PL Pot Factor
PL Pot Factor is an A/D value from the potentiometer which allows the iNetVu™ Mobile
Software to convert the A/D value of the Potentiometer into an equivalent angle. The PL
Pot Factor should vary approximately +15% from the Default values (see appendix 3).
The PL Pot Factor is calculated during the Polarization Calibration process. The user
may edit these values through this window, however any changes may result in failure to
recognize the angle value.
Polarization Offset
By default this polarization-offset value is set to +0°. If there happens to be a
requirement for a polarization offset, the user may manually enter this value at in this
area.
Slow Speed
The iNetVu
TM
software basis the default polarization motor slow speed on the platform
size and type. See appendix 3, table 5 for details. The user may change this value,
however changing such value could result in difficulty for satellite acquisition.