AZ Pot Zero
AZ Pot Zero is an A/D value from the potentiometer calculated upon azimuth
calibration which physically determines where the iNetVu™ Mobile Software
places Azimuth Angle 0°. The AZ Pot Zero may vary approximately +15% from
the Default values (see appendix 3, table 5). The user may edit these values
through this menu, however any changes may result in failure to recognize the
correct 0° angle.
AZ Pot Factor
AZ Pot Factor is an A/D value from the potentiometer calculated upon azimuth
calibration which allows the iNetVu™ Mobile Software to convert the A/D value of the
Potentiometer into an equivalent angle. The AZ Pot Factor should vary approximately
+15% from the Default values (see appendix 3, table 5). The user may edit these values
through this window, however any changes may result in failure to recognize the correct
azimuth angles.